Teilenummer AA14520

Fluid Pressure Regulating Valve

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
aa14520
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
004742252

Informationen zum Teil
10 gpm maximum flow capacity at maximum rated inlet and outlet pressures

NSN
Nationale Bestandsnummer:
4820-00-474-2252 4820004742252
TXT
Beschreibung:
Fluid Pressure Regulating Valve
INC
INC
Artikelname-Code:
27565
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Aluminum alloy
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the outside surface.AAJP
Outside Surface Treatment:
Any acceptable
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Tee angle
MRC:
Items furnished as accessories which are not specified elsewhere.ABFF
Furnished Items:
Automatic relief valve
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Fluid, petroleum base
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal tube
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
First End Outside Diameter Tube Accommodated:
0.500 inches
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
First End Thread Size And Series/type Designator:
3/4-16 unf
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACLK
First End Thread Class:
2b
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
Indicates whether or not the third end is identical with first or second end.ACMX
Third End Relationship With Preceding Ends:
Not identical with first or second end
MRC:
A narrative description of the type of end connection.ACMY
Third End Connection Type:
Threaded internal tube
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACNW
Third End Outside Diameter Tube Accommodated:
0.250 inches
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACNX
Third End Thread Size And Series/type Designator:
7/16-20 unf
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACNY
Third End Thread Class:
2b
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACNZ
Third End Thread Direction:
Right-hand
MRC:
The element,compound,or mixture of which the seating surfaces are fabricated.ACSH
Seat Material:
Steel, corrosion resisting
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Cone, top guided
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Steel, corrosion resisting
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
3
MRC:
The minimum to maximum limits of outlet pressure of the item.AEVA
Outlet Pressure Range:
+800.0/+1050.0 pounds per square inch
MRC:
The minimum to maximum limits of outlet pressure of the item.AEVA
Outlet Pressure Range:
+800.0 to 1050.0 pounds per square inch
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Automatic double stage
MRC:
The seat design of the valve stem.AEVQ
Valve Stem Design:
Double seat
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
The means whereby a valve is actuated other than by the media passing through it.AEVS
Remote Actuation Method:
Spool
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
800.0 pounds per square inch
MRC:
The rated variance of the outlet pressure from the set pressure.AEWB
Outlet Pressure Accuracy Rating:
Not rated
MRC:
An indication of whether or not a filter is included.AEWF
Filter:
Not included

Ähnlich Fluid Pressure Regulating Valves

« Nonpowered Valves {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken