Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Fluid Pressure Regulating Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Nickel copper alloy
First End Flange Outside Diameter:
Between 9.740 inches and 9.760 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Tee
MRC:
The element, compound,or mixture of which the stem is fabricated,excluding any surface treatment.ABEP
Stem Material:
Bronze
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Recessed flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Recessed
First End Recess Diameter:
Between 5.118 inches and 5.120 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the shape of the end flange.ACKT
First End Flange Shape Style:
Round w/ bolt holes
MRC:
A measurement of the smallest dimension of the first end flange, in distinction from length or width.ACKU
First End Flange Thickness:
Between 1.490 inches and 1.510 inches
MRC:
The number of bolt holes provided on the item.ACKZ
First End Bolt Hole Quantity:
12
MRC:
The length of a straight line which passes through the center of a bolt hole,and terminates at the circumference.ACLA
First End Bolt Hole Diameter:
0.688 inches
First End Bolt Circle Diameter:
8.250 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
Indicates whether or not the third end is identical with first or second end.ACMX
Third End Relationship With Preceding Ends:
Identical with first end
Face To Face Distance:
17.500 inches
First Connection Face To Centerline Distance:
11.812 inches
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk, plug type
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Nickel copper alloy
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
3
MRC:
The means other than the end connection/s/ by which the item may be mounted.ADZJ
Mounting Facility:
Flange
MRC:
The minimum to maximum limits of outlet pressure of the item.AEVA
Outlet Pressure Range:
+3.0/+15.0 pounds per square inch
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Automatic single stage
MRC:
The seat design of the valve stem.AEVQ
Valve Stem Design:
Double seat
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
The means whereby a valve is actuated other than by the media passing through it.AEVS
Remote Actuation Method:
Diaphragm
MRC:
An indication of whether or not a filter is included.AEWF
Filter:
Not included
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Zzzy
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Quality control iaw navships 0948-045-7010 material identification and control instruction for level 1 items