Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Logarithmic detector/controller
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Linear Microcircuit				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Iiilength:
					
					
						3.00 millimeters 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Iiiheight:
					
					
						1.10 millimeters 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Iiiwidth:
					
					
						4.90 millimeters 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						3.00 millimeters 					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-40.0 to 85.0 degrees celsius					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Wideband					
				 
							
					
						MRC:
						Indicates the physical configuration of the inclosure.CQSZ
					 
					
						Inclosure Configuration:
					
					
						Dual-in-line					
				 
							
					
						MRC:
						The basic purpose and number of functions of the device,modified by its intended use.CSSL
					 
					
						Design Function And Quantity:
					
					
						1 amplifier,  log and 1 control					
				 
							
					
						MRC:
						The value of the voltage applied and type of specific electrical characteristic for which the item is designed.CZEN
					 
					
						Voltage Rating And Type Per Characteristic:
					
					
						5.5 volts  total supply					
				 
							
					
						MRC:
						Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
					 
					
						Special Features:
					
					
						Pb-free,  rohs compliant;  power down feature provided;  item uses a cascade of eight amplifier/limiter cells;  at each amplifier output,  a detector/rectifier cell is used to convert the rf signal to baseband form;  a ninth detector cell is placed directly at the input of the ad8313					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						8 flat leads