Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Sonar Test Set
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
11.700 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
20.500 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 105.0 volts and 130.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 58.0 hertz and 62.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Test set, sonar; junction box; cable assembly, special purpose, electrical; cable assembly, special purpose, electrical; cable assembly, special purpose, electrical; cable assembly, power8 electrical; cable assembly, power electrical; cable assembly, power8 electrical
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 and 1 and 1 and 1 and 1 and 1 and 1 and 1
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Jcens; jcens; jcens; jcens; jcens; jcens; jcens; jcens; jcens
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Ts-754/bqm-1 type no.
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/carrying case
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Measures ac signals up to 10 v, facilities for injecting sinusoidal voltage into the alignment signal circuits, facilities for navy model ocp connection, facilities to provide signals to test target hydraphone
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Frequency range, 1000 to 40000 cycles, output level 40 to 120 db below 1 volt, noise output 1 ohm impedance
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
11.000 inches