Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Radar Test Set
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
20.625 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
21.375 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 1000.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Cabinet; cable; cable; case; delay line; delay line; delay line; delay line; delay line; indicator; power supply
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 and 1 and 1 and 1 and 1 and 1 and 1 and 1 and 1 and 1 and 1
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Jcens
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Cy-1319/upm type no. And cg-546/u type no. And cg-579/u type no. And cy-1318/upm type no. And mx-1448/up type no. And mx-1449/up type no. And mx-1450/up type no. And mx-1451/up type no. And mx-1452/up type no. And ts-577/up type no. And pp-910/upm type no.
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Aluminum carrying case
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Multiple item w/carrying case
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Measure subclutter visibility at if; phase detector characteristics; if, video pulse jitter; continuous wave, pulsed if of signal generator
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Signal generator; range 27 to 33 megacycles, output 22.4 microvolts to 224 millivolts, pulse repetition frequency 50 to 6000 cycles, pulse jitter tester, sine wave sweep frequency 258 kc, range 27 to 33 megacycles, porm 10 per cent accuracy
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
33.437 inches