Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Pulse Generator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
23.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
15.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.750 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
General purpose
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
Not rated
MRC:
The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
Shock Resistance Rating In Gravitational Units:
Not rated
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-40.0/+55.0 degrees celsius
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-40.0 to 55.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Hours
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
A designation assigned to the item for purpose of ready identification.AJKH
Identification Designator:
Anupm15-80058
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
6000.0 feet
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Manual
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Portable
MRC:
Indicates the type of control.AQZF
Control Type:
Local
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Electron tube
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
Not rated
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
Not rated
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
275.0 watts output
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
100.000 volts output
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
Not rated
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
2.500 kilohms output channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms output channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
2.500 kilohms output channel
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms output channel
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
1.500 microseconds output channel
MRC:
The length of time it takes the pulse to rise per channel.BHTQ
Pulse Rise Time Per Channel:
250.000 nanoseconds output channel err-100
MRC:
The length of time it takes the pulse to rise per channel.BHTQ
Pulse Rise Time Per Channel:
50.000 nanoseconds output channel err-100
MRC:
The length of time it takes the pulse to rise per channel.BHTQ
Pulse Rise Time Per Channel:
250.000 nanoseconds output channel
MRC:
The length of time it takes the pulse to rise per channel.BHTQ
Pulse Rise Time Per Channel:
50.000 nanoseconds output channel
MRC:
The length of time it takes the trailing edge of the pulse to fall per channel.BHTR
Pulse Decay Time Per Channel:
100.000 nanoseconds output channel err-100
MRC:
The length of time it takes the trailing edge of the pulse to fall per channel.BHTR
Pulse Decay Time Per Channel:
300.000 nanoseconds output channel err-100
MRC:
The length of time it takes the trailing edge of the pulse to fall per channel.BHTR
Pulse Decay Time Per Channel:
100.000 nanoseconds output channel
MRC:
The length of time it takes the trailing edge of the pulse to fall per channel.BHTR
Pulse Decay Time Per Channel:
300.000 nanoseconds output channel
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Negative output channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Positive output channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Negative output channel
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Positive output channel
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
10.000 kilopulses per second operating channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
50.000 pulses per second operating channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
10.000 kilopulses per second operating channel
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
50.000 pulses per second operating channel
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
50.000 volts output channel
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Output channel pulse
MRC:
The limits of calbration,expressed in percent.BJBH
Calibrated Tolerance In Percent:
-10.0/+10.0
MRC:
The limits of calbration,expressed in percent.BJBH
Calibrated Tolerance In Percent:
-10.0 to 10.0
MRC:
The physical configuration of the output wave.BJBJ
Output Wave Shape:
Sawtooth
MRC:
Indicates the type and number of indicator device(s) included.BJBL
Indicator Device Type And Quantity:
1 light
MRC:
The maximum time an item will continuously run,expressed in hours.BJBM
Maximum Continuous Operating Time In Hours:
Not rated
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Receptacle, power front and receptacle, coaxial front
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
1000.0 single voltage
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
50.0 single voltage
MRC:
A designation of the function which is calibrated.BJBS
Calibration Function:
Pulse repetition
MRC:
Indicates the type and number of contact(s) included in the connection.BJBW
Connection Contact Type And Quantity:
3 receptacle, coaxial internal and 1 receptacle, power external
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
115.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single