Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Radio Interference Measuring Set
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
10.375 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
24.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
12.625 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 110.0 volts and 125.0 volts and 210.0 volts and 250.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 400.0 hertz and 50.0 hertz and 400.0 hertz
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+20.0/+400.0 megahertz
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The name designation of the written or printed document.ALYQ
Document Title:
Department of the navy technical maual navships 93147
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Voltmeter and decibel meter
MRC:
The total opposition (resistive and reactive) presented by the item to an alternating current source.AMND
Input Impedance Rating:
50.0 ohms
MRC:
The number of specified ranges of frequencies or wavelengths operating between two stated limits.ANLC
Frequency Band Quantity:
6
MRC:
The number of transmission paths in the item.ANLD
Frequency Channel Quantity:
6
MRC:
The minimum and maximum deviation from the exact reading at full scale deflection.ANTD
Scaleaccuracy Rating In Percent:
-1.000/+1.000
MRC:
An indication of the scale range.APSK
Scale Range:
+1.0/+100.0 microvolts and +0.0/+40.0 decibels
MRC:
The limits of permissible variance from the standard/true value,expressed in percent.AREL
Frequency Calibration Accuracy Range In Percent:
-2.0/+2.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single