Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						apgn11-1rec4-41-501					
 
					
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Circuit Breaker				
			 
			
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Multipole-single actuator type					
				 
							
					
						MRC:
						A measurement of the longest dimension of a bushing,in distinction from width.ABXD
					 
					
						Bushing Length:
					
					
						0.495 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						2.000 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						1.500 inches 					
				 
							
					
						MRC:
						The center to center distance between terminals parallel to the length of the item.AEBP
					 
					
						Center To Center Distance Between Terminals Parallel To Length:
					
					
						1.530 inches 					
				 
							
					
						MRC:
						The center to center distance between terminals parallel to the width of the item.AEBQ
					 
					
						Center To Center Distance Between Terminals Parallel To Width:
					
					
						0.750 inches 					
				 
							
					
					
						Mounting Surface To Terminal End Distance:
					
					
						2.200 inches 					
				 
							
					
						MRC:
						The number of poles included in the item.AKPX
					 
					
						Pole Quantity:
					
					
						2					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 threaded bushing w/panel seal					
				 
							
					
						MRC:
						The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
					 
					
						Thready Qty Per Inch (tpi):
					
					
						32					
				 
							
					
						MRC:
						The maximum current load that each pole is rated to carry continuously.CPLM
					 
					
						Maximum Continuous Load Current Rating Per Pole:
					
					
						0.5 amperes ac all locations					
				 
							
					
						MRC:
						Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
					 
					
						Operating Voltage Type And Rating Per Pole In Volts:
					
					
						250.0 ac all locations					
				 
							
					
						MRC:
						Indicates the type of electrical condition that will cause the device to trip.CPRH
					 
					
						Circuit Protection Type:
					
					
						Overcurrent all locations					
				 
							
					
						MRC:
						The means by which the trip mechanism is released.CPRJ
					 
					
						Trip Release Method:
					
					
						Magnetic-hydraulic all locations					
				 
							
					
						MRC:
						Denotes the type of trip release action.CPRL
					 
					
						Trip Release Characteristic:
					
					
						Time delay all locations					
				 
							
					
						MRC:
						The means provided to reposition the mechanism so that the device is ready to function.CPRQ
					 
					
						Reset Method:
					
					
						Manual					
				 
							
					
						MRC:
						Indicates the type of mechanism provided for tripping main contacts.CPRR
					 
					
						Main Contact Tripping Mechanism Type:
					
					
						Trip free					
				 
							
					
						MRC:
						Indicates the type and number of actuators provided for manual control.CPRT
					 
					
						Manual Actuator Type And Quantity:
					
					
						1 toggle					
				 
							
					
						MRC:
						The function for which the auxiliary switch is designed and the number provided.CPRZ
					 
					
						Auxiliary Switch Function And Quantity:
					
					
						1 control					
				 
							
					
						MRC:
						The basic internal electrical configuration of the trip mechanism.CPSM
					 
					
						Internal Trip Release Configuration:
					
					
						Series trip w/auxiliary load terminal all locations					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.500 inches					
				 
							
					
						MRC:
						Indicates the location of the switch in relation to its designated position.CQSM
					 
					
						Switch Location And Position Designation:
					
					
						Internal at pole one					
				 
							
					
						MRC:
						The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.CQWN
					 
					
						Trip Delay Time In Seconds Per Rated Continuous Current:
					
					
						0.500  at 150 pct all locations and 8.000  at 150 pct all locations and 0.150  at 200 pct all locations and 1.900  at 200 pct all locations and 0.020  at 400 pct all locations and 0.400  at 400 pct all locations and 0.006  at 600 pct all locations and 0.250  at 600 pct all locations and 0.004  at 800 pct all locations and 0.100  at 800 pct all locations and 0.004  at 1000 pct all locations and 0.050  at 1000 pct all locations					
				 
							
					
						MRC:
						Indicates the type of protection for which the inclosure is designed.CQXF
					 
					
						Inclosure Protection Type For Which Designed:
					
					
						Moisture resistant and corrosion resistant and shock resistant and vibration resistant					
				 
							
					
						MRC:
						Indicates the type of terminal for providing electrical connection to the switch.CRTK
					 
					
						Switch Terminal Type:
					
					
						Quick disconnect,  male					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						400.0 all locations					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					
						Un					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						10 quick disconnect,  male