Teilenummer APL-1-1-51-303-H

Circuit Breaker

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
apl-1-1-51-303-h
Entmilitarisierung:
Lagerfähigkeit:
Maßeinheit:
NIIN:
016262112

Informationen zum Teil
Hydraulic magnetic circuit protector

NSN
Nationale Bestandsnummer:
5925-01-626-2112 5925016262112
TXT
Beschreibung:
Circuit Breaker
INC
INC
Artikelname-Code:
00136
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Single pole type
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.530 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.755 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Plastic
MRC:
The center to center distance between terminals parallel to the length of the item.AEBP
Center To Center Distance Between Terminals Parallel To Length:
1.940 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.060 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
CONT-RO-L,R-ECEI
MRC:
None.AJEC
Boss Height:
0.150 inches
MRC:
None.AJWX
Mounting Surface To Terminal End Distance:
2.495 inches
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
The maximum current load that each pole is rated to carry continuously.CPLM
Maximum Continuous Load Current Rating Per Pole:
30.0 amperes dc all locations
MRC:
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
Operating Voltage Type And Rating Per Pole In Volts:
65.0 dc all locations
MRC:
Indicates the type of electrical condition that will cause the device to trip.CPRH
Circuit Protection Type:
Overvoltage all locations
MRC:
The means by which the trip mechanism is released.CPRJ
Trip Release Method:
Magnetic-hydraulic all locations
MRC:
Denotes the type of trip release action.CPRL
Trip Release Characteristic:
Time delay all locations
MRC:
The means provided to reposition the mechanism so that the device is ready to function.CPRQ
Reset Method:
Manual
MRC:
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.CQWN
Trip Delay Time In Seconds Per Rated Continuous Current:
1.0 at 125 pct and 18.0 at 125 pct all locations
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 threaded stud

Ähnlich Circuit Breakers

« Circuit Breakers {lang[catalog]}
Jetzt vergleichen»