Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
as25244-pt-30
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Circuit Breaker
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Single pole type
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.189 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.750 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Plastic
MRC:
The center to center distance between terminals parallel to the length of the item.AEBP
Center To Center Distance Between Terminals Parallel To Length:
1.188 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
1.812 inches
Mounting Surface To Terminal End Distance:
2.000 inches
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
The maximum current load that each pole is rated to carry continuously.CPLM
Maximum Continuous Load Current Rating Per Pole:
30.0 amperes ac single location and 30.0 amperes dc single location
MRC:
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
Operating Voltage Type And Rating Per Pole In Volts:
115.0 ac single location and 28.0 dc single location
MRC:
Indicates the type of electrical condition that will cause the device to trip.CPRH
Circuit Protection Type:
Overcurrent single location
MRC:
The means by which the trip mechanism is released.CPRJ
Trip Release Method:
Thermal single location
MRC:
Denotes the type of trip release action.CPRL
Trip Release Characteristic:
Time delay single location
MRC:
The means provided to reposition the mechanism so that the device is ready to function.CPRQ
Reset Method:
Manual
MRC:
Indicates the type of mechanism provided for tripping main contacts.CPRR
Main Contact Tripping Mechanism Type:
Trip free
MRC:
The basic internal electrical configuration of the trip mechanism.CPSM
Internal Trip Release Configuration:
Series trip single location
MRC:
The temperature of the medium surrounding the trip release at which it can be operated continuously.CRCF
Trip Release Ambient Tempurature Rating:
-40.0 degrees celsius single location and 71.0 degrees celsius single location
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0 single location
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 screw