Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Non Wire Wound Variable Resistor				
			 
			
										
					
						MRC:
						The number of individual elements.AAPN
					 
					
						Section Quantity:
					
					
						1					
				 
							
					
						MRC:
						An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
					 
					
						Reliability Indicator:
					
					
						Not established					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
					 
					
						Shaft Diameter:
					
					
						0.250 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the shaft,in distinction from width.ABXF
					 
					
						Shaft Length:
					
					
						0.220 inches 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
					 
					
						Shaft Style:
					
					
						Round					
				 
							
					
						MRC:
						Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
					 
					
						Actuator Type:
					
					
						Single shaft					
				 
							
					
						MRC:
						That part of the total rotational travel of the actuator that produces a change in output,expressed in degree angular rotation.AEFH
					 
					
						Effective Electrical Rotation In Deg Angular Rotation:
					
					
						269.5 					
				 
							
					
						MRC:
						The maximum amount of turning force required to initiate the actuator movement.AEFK
					 
					
						Maximum Starting Torque:
					
					
						0.60 inch-ounces					
				 
							
					
						MRC:
						The maximum amount of force requred to maintain actuator movement.AEFL
					 
					
						Maximum Running Torque:
					
					
						0.60 inch-ounces					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Flange					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Nonmetallic shaft					
				 
							
					
						MRC:
						A measure of the opposition to the flow of direct or alternating current per section.CQCC
					 
					
						Electrical Resistance Per Section:
					
					
						4.211 kilohms single section					
				 
							
					
						MRC:
						The location per section,in degrees,of effective electrical rotation between the counterclockwise terminal of a resistor and each tap terminal.CQCH
					 
					
						Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
					
					
						97.7 single section					
				 
							
					
						MRC:
						The measurement of the rotary mechanical motion of the actuating shaft of an item,expressed in degrees.CQCK
					 
					
						Rotary Actuator Travel In Angular Deg:
					
					
						360.0 					
				 
							
					
						MRC:
						The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
					 
					
						Power Dissipation Rating Per Section In Watts:
					
					
						4.0 free air single section					
				 
							
					
						MRC:
						The number of fixed terminals at points between the end terminals that provide connection to the intermediate values of the total value per section.CRJS
					 
					
						Fixed Tap Quantity Per Section:
					
					
						1 single section					
				 
							
					
						MRC:
						The limits of permissible variation from the rated value of the location of a tap per section.CRKS
					 
					
						Tap Location Tolerance Per Section:
					
					
						-0.6/+0.6 degrees angular rotation single section					
				 
							
					
						MRC:
						The limits of permissible variation from the rated value of the location of a tap per section.CRKS
					 
					
						Tap Location Tolerance Per Section:
					
					
						-0.6 to 0.6 degrees angular rotation single section					
				 
							
					
						MRC:
						The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
					 
					
						Resistance Tolerance Per Section In Percent:
					
					
						-1.0/+1.0 single section					
				 
							
					
						MRC:
						The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
					 
					
						Resistance Tolerance Per Section In Percent:
					
					
						-1.0 to 1.0 single section					
				 
							
					
						MRC:
						The feature that controls the actuator travel.CRSX
					 
					
						Actuator Travel Control Feature:
					
					
						Stops					
				 
							
					
						MRC:
						The rate of change and distribution of resistance per section,in relation to the rotation of the control shaft,which establishes a standard taper curve designated by an alphabetic character and accepted for common usage.CSDL
					 
					
						Standard Taper Curve Per Section:
					
					
						A single section					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						6 solder stud