Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Telegraph-telephone Si Converter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
10.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
17.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
117.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Converter, telephone signal
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
Cv-566/gt
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
Indicates the type of signalling the item will perform.ANEQ
Signal Type:
Ring down and supervisory
MRC:
Indicates the type of switchboard side current,whether alternating or direct.BGGY
Switchboard Side Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which the switchboard received signal is rated.BGHB
Err Default:
Err default and err default
MRC:
The number of complete cyclic changes,per unit of time,for which the switchboard received signal is rated.BGHB
Received Switchboard Signal Frequency Rating:
Between 16.0 hertz and 60.0 hertz
MRC:
The number of complete cyclic changes,per unit of time,for which the switchboard transmitted signal is rated.BGHC
Err Default:
Err default and err default
MRC:
The number of complete cyclic changes,per unit of time,for which the switchboard transmitted signal is rated.BGHC
Transmitted Switchboard Signal Frequency Rating:
Between 16.0 hertz and 60.0 hertz
MRC:
The value,or range of values,of direct current potential for which the received signal is rated.BGHD
Err Default:
Err default
MRC:
The value,or range of values,of direct current potential for which the received signal is rated.BGHD
Received Signal Dc Voltage Rating:
48.0 volts
MRC:
The value,or range of values,of direct current potential for which the transmitted signal is rated.BGHF
Err Default:
Err default
MRC:
The value,or range of values,of direct current potential for which the transmitted signal is rated.BGHF
Transmitted Signal Dc Voltage Rating:
48.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which the transmitted line signal is rated.BGHG
Transmitted Line Signal Frequency Rating:
300.0 hertz
MRC:
The number of complete cyclic changes,per unit of time,for which the received line signal is rated.BGHH
Received Line Signal Frequency Rating:
300.0 hertz
MRC:
The number of communication circuits provided.BGHJ
Communication Circuit Quantity:
1 and 3
MRC:
The number of alternating current phases.FAAZ
Phase:
Single