Teilenummer BIS21T-6-RG

Fault Locating Indicator

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
bis21t-6-rg
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
010607984

Informationen zum Teil
Magnetic latching; threaded body mounting provision

NSN
Nationale Bestandsnummer:
6625-01-060-7984 6625010607984
TXT
Beschreibung:
Fault Locating Indicator
INC
INC
Artikelname-Code:
60639
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the circumference.ABMZ
Diameter:
Between 0.320 inches and 0.380 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
Between 0.820 inches and 0.880 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
6.0 volts
MRC:
The number of contacts which provide electrical connection.AFRA
Contact Quantity:
4
MRC:
Indicates the type of contact(s) included on the item.AKSF
Contact Type:
Wire hook
MRC:
Indicates the type of presentation.AMNL
Presentation Type:
Drop flags
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 threaded case
MRC:
The opposition that the coil offers to the flow of direct current.BDFT
Coil Dc Resistance:
55.0 ohms
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Coil and hermetically sealed case and waterproof
MRC:
The chemical compound or mechanical mixture properties of which the case is fabricated.CWJK
Case Material:
Aluminum
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
No fault indicator side is green

Ähnlich Fault Locating Indicators

« Electrical and Electronic Properties Measuring and Testing Instruments {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken