Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Sensitive Switch				
			 
			
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Hole mounted					
				 
							
					
						MRC:
						The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
					 
					
						Hazardous Locations/environmental Protection:
					
					
						Weatherproof					
				 
							
					
						MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Metal					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.220 inches 					
				 
							
					
						MRC:
						The measurement of the distance that the actuator protrudes from the body.AFGK
					 
					
						Actuator Length:
					
					
						1.560 inches 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
					 
					
						Actuator Style:
					
					
						Roller arm					
				 
							
					
					
						Actuator Free Position Height:
					
					
						2.220 inches 					
				 
							
					
					
						Actuator Roller Diameter:
					
					
						0.750 inches 					
				 
							
					
					
						Actuator Roller Width:
					
					
						0.310 inches 					
				 
							
					
					
						Housing Height:
					
					
						1.800 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the housing,in distinction from width.AFWD
					 
					
						Housing Length:
					
					
						3.900 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of a housing,in distinction from thickness.AFWE
					 
					
						Housing Width:
					
					
						1.020 inches 					
				 
							
					
					
						Center To Center Distance Between Housing Mounting Facilities Parallel To Height:
					
					
						1.220 inches 					
				 
							
					
					
						Center To Center Distance Between Housing Mounting Facilities Parallel To Length:
					
					
						2.950 inches 					
				 
							
					
						MRC:
						The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
					 
					
						Maximum Voltage Rating In Volts:
					
					
						250.0 dc and 600.0 ac					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						6640-00-902-9711					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Unthreaded hole					
				 
							
					
						MRC:
						The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
					 
					
						Nonpile-up Contact Arrangement:
					
					
						1 pole,  double throw,  one position momentary single switch unit					
				 
							
					
						MRC:
						The amount to which the actuating force must be reduced to permit the switch to become unactuated.CRRM
					 
					
						Switch Release Force:
					
					
						2.000 ounces 					
				 
							
					
						MRC:
						The amount of force required to actuate the switch.CSJN
					 
					
						Switch Actuating Force:
					
					
						Between 10.0 ounces and 20.0 ounces 					
				 
							
					
						MRC:
						The movement of the switch actuator.CXQQ
					 
					
						Actuator Movement:
					
					
						Between 0.188 pretravel inches  and 0.219 overtravel inches and 0.006 differential inches 					
				 
							
					
						MRC:
						The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
					 
					
						Contact Load Current Rating At Maximum Rated Voltage:
					
					
						0.250 amperes resistive dc and 2.000 amperes resistive ac					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						3 screw