Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
c114tpls-112
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Centrifugal Pump Unit
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Frame
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Threaded internal
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded internal
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
30.0 gallons per minute
MRC:
The sum of the total discharge head and the total suction lift.AHYX
Total Head:
100.000 feet
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
A measurement of the longest dimension of an item unencumbered by packaging or packing,in distinction from width.AJAF
Unpackaged Unit Length:
15.400 inches
MRC:
A measurement from the bottom to the top of an item unencumbered by packaging or packing,in distinction from depth.AJAH
Unpackaged Unit Height:
8.875 inches
MRC:
The element,compound,or mixture of the basic material of which the major portion of the pump is fabricated.AJAL
Pump Basic Material:
Iron
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
1.500 horsepower
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0 and 230.0
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0