Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Thermostatic Switch				
			 
			
										
					
						MRC:
						A measurement of the longest dimension of a capillary tube.AEVT
					 
					
						Capillary Tube Length:
					
					
						26.000 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of a bulb.AEVU
					 
					
						Bulb Length:
					
					
						5.500 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
					 
					
						Bulb Diameter:
					
					
						0.469 inches 					
				 
							
					
						MRC:
						The longest distance between mounting centers parallel to the horizontal plane.AFDS
					 
					
						Longest Horizontal Distance Between Mounting Centers:
					
					
						1.312 inches 					
				 
							
					
						MRC:
						The shortest distance between mounting centers parallel to the horizontal plane.AFDT
					 
					
						Shortest Horizontal Distance Between Mounting Centers:
					
					
						0.656 inches 					
				 
							
					
						MRC:
						The longest distance between mounting centers parallel to the vertical plane.AFDV
					 
					
						Longest Vertical Distance Between Mounting Centers:
					
					
						1.219 inches 					
				 
							
					
						MRC:
						The shortest distance between mounting centers parallel to the vertical plane.AFDW
					 
					
						Shortest Vertical Distance Between Mounting Centers:
					
					
						0.609 inches 					
				 
							
					
						MRC:
						Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
					 
					
						Tempurature Sensing Element Type:
					
					
						Capillary tube-bulb					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Bracket and unthreaded hole					
				 
							
					
						MRC:
						The general configuration and relative position of the facilities provided for mounting the item.CQYJ
					 
					
						Mounting Facility Pattern:
					
					
						Four position diamond					
				 
							
					
						MRC:
						The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
					 
					
						Nonpile-up Contact Arrangement:
					
					
						1 pole,  double throw,  both positions maintained					
				 
							
					
						MRC:
						Indicates the type of terminal for providing electrical connection to the item.CSCF
					 
					
						Terminal Type:
					
					
						Tab,  solder lug					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						20.0 amperes resistive load single voltage					
				 
							
					
						MRC:
						The adjustability of the contact.CTYC
					 
					
						Contact Adjustability:
					
					
						Actuation point adjustable					
				 
							
					
						MRC:
						The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
					 
					
						Contact Adjustment Range:
					
					
						+60.00/+98.00 actuation point degrees fahrenheit					
				 
							
					
						MRC:
						Indicates the type of device provided for manual adjustment of the contact(s).CTYS
					 
					
						Contact Adjustment Type:
					
					
						External actuation point knob					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						115.0 ac at sea level single voltage