Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						ca2-b0-16-650-121-c					
 
					
					
					
					
				 
			 
							
					
						Informationen zum Teil
						C series,  circuit breaker
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Circuit Breaker				
			 
			
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Multipole-multiple actuator type					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						2.500 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						1.515 inches 					
				 
							
					
						MRC:
						The center to center distance between terminals parallel to the length of the item.AEBP
					 
					
						Center To Center Distance Between Terminals Parallel To Length:
					
					
						1.940 inches 					
				 
							
					
						MRC:
						The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
					 
					
						Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
					
					
						2.062 inches 					
				 
							
					
						MRC:
						The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
					 
					
						Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
					
					
						0.750 inches 					
				 
							
					
					
						Boss Height:
					
					
						0.150 inches 					
				 
							
					
					
						Mounting Surface To Terminal End Distance:
					
					
						2.723 inches 					
				 
							
					
						MRC:
						The number of poles included in the item.AKPX
					 
					
						Pole Quantity:
					
					
						2					
				 
							
					
						MRC:
						The maximum current load that each pole is rated to carry continuously.CPLM
					 
					
						Maximum Continuous Load Current Rating Per Pole:
					
					
						50.0 amperes dc all locations					
				 
							
					
						MRC:
						Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
					 
					
						Operating Voltage Type And Rating Per Pole In Volts:
					
					
						80.0 dc all locations					
				 
							
					
						MRC:
						Indicates the type of electrical condition that will cause the device to trip.CPRH
					 
					
						Circuit Protection Type:
					
					
						Overcurrent all locations					
				 
							
					
						MRC:
						The means by which the trip mechanism is released.CPRJ
					 
					
						Trip Release Method:
					
					
						Magnetic all locations					
				 
							
					
						MRC:
						Denotes the type of trip release action.CPRL
					 
					
						Trip Release Characteristic:
					
					
						Time delay all locations					
				 
							
					
						MRC:
						The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.CPRN
					 
					
						Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
					
					
						62.5 all locations					
				 
							
					
						MRC:
						The means provided to reposition the mechanism so that the device is ready to function.CPRQ
					 
					
						Reset Method:
					
					
						Manual					
				 
							
					
						MRC:
						Indicates the type of mechanism provided for tripping main contacts.CPRR
					 
					
						Main Contact Tripping Mechanism Type:
					
					
						Nontrip free					
				 
							
					
						MRC:
						The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.CQWN
					 
					
						Trip Delay Time In Seconds Per Rated Continuous Current:
					
					
						45.0  at 125 pct  and 345.0  at 125 pct all locations					
				 
							
					
						MRC:
						Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
					 
					
						Special Features:
					
					
						Used on boatalt 38rp