Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
cc15dhy3.522-32
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
Base temperature rating minus 55 degrees c to 100 degrees c, altitude rating sea level to infinity
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.812 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.750 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetically sealed
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
24.0 dc volts single operating power rqmt and 30.0 dc volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
14.0 dc volts 1st power output and 16.0 dc volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-14.0 dc volts 2nd power output and -16.0 dc volts 2nd power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 1st power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 2nd power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 2nd power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 1st power output
MRC:
The means used to change alternating current voltage to direct current voltage.BHQN
Rectification Method:
Single phase full wave center tap
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Filter
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
3.5 dc amperes 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
3.5 dc amperes 1st power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Top panel 1st power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Top panel 2nd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 2nd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 1st power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Ferrule 1st power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Ferrule 2nd power output
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Ferrule single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
2 single operating power rqmt