Teilenummer CF2Z34-1

Circuit Breaker

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
cf2z34-1
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
010455150
NSN
Nationale Bestandsnummer:
5925-01-045-5150 5925010455150
TXT
Beschreibung:
Circuit Breaker
INC
INC
Artikelname-Code:
00136
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Multipole-multiple actuator type
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.164 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
5.844 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
2.064 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 2.577 inches and 2.641 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Plastic
MRC:
The center to center distance between terminals parallel to the length of the item.AEBP
Center To Center Distance Between Terminals Parallel To Length:
3.546 inches
MRC:
The center to center distance between terminals parallel to the width of the item.AEBQ
Center To Center Distance Between Terminals Parallel To Width:
1.032 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.750 inches
MRC:
The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.032 inches
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately rugged
MRC:
None.AJEC
Boss Height:
0.218 inches
MRC:
None.AJWX
Mounting Surface To Terminal End Distance:
2.609 inches
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
2
MRC:
The means of quenching an arc.APNQ
Arc Quenching Method:
Magnetic blowout
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 threaded hole and 4 slot
MRC:
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
Storage Type:
General purpose warehouse
MRC:
The unusual or unique characteristic/s/ or quality/ies/ of an item which necessitates the establishment of a requirement for special handling.BBRJ
Special Handling Feature:
Magnetic
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
32
MRC:
Indicates the type of electrical condition that will cause the device to trip.CPRH
Circuit Protection Type:
Overcurrent all locations
MRC:
The means by which the trip mechanism is released.CPRJ
Trip Release Method:
Magnetic-hydraulic all locations
MRC:
The means provided to reposition the mechanism so that the device is ready to function.CPRQ
Reset Method:
Manual
MRC:
Indicates the type of mechanism provided for tripping main contacts.CPRR
Main Contact Tripping Mechanism Type:
Trip free
MRC:
Indicates the type and number of actuators provided for manual control.CPRT
Manual Actuator Type And Quantity:
2 toggle
MRC:
Denotes the action imparted by actuator operation.CPRW
Actuator Function:
Trip-reset
MRC:
An indication of the designated position of the actuator.CPRX
Actuator Position Designation:
At each pole
MRC:
Indicates the arrangement of the externally connected actuators.CPRY
External Actuator Linkage Arrangement:
One and two linked
MRC:
The basic internal electrical configuration of the trip mechanism.CPSM
Internal Trip Release Configuration:
Series trip all locations
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.138 inches
MRC:
Indicates the type of protection for which the inclosure is designed.CQXF
Inclosure Protection Type For Which Designed:
Dustproof
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 screw

Ähnlich Circuit Breakers

« Circuit Breakers {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken