Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
cm30100s1ebstd
Informationen zum Teil
Universal process controller, 1/4 din
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Controller Electrical
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.800 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.800 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Manual
MRC:
Indicates the performance capability of the item or component.AGLD
Performance Type:
Manual
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Standard
MRC:
An indication of the characteristic of the operating voltage.ANCN
Operating Voltage Characteristic:
Full
MRC:
The voltage required to actuate the item.ANDE
Actuator Voltage:
10.0 dc and 36.0 dc
MRC:
The temperature of the medium surrounding an item at which it can be operated.ANDX
Ambient Temp:
32.0 degrees fahrenheit and 131.0 degrees fahrenheit
MRC:
An indication of whether or not the item is designed in conformance with the national electrical manufacturers association (nema) standards.ANQC
National Electrical Manufacturers Association Standards Design:
Not designed per nema std
MRC:
Indicates the type of control.AQZF
Control Type:
Local
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
2 analog inputs, 1 analog output, and 2 relays; power supply is 10.0 - 36.0 vdc