Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Rotometer flowmeter
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Flow Rate Indicating Meter				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						4.0 inches 					
				 
							
					
						MRC:
						A narrative description of the type of inlet connection.ACQW
					 
					
						Inlet Connection Type:
					
					
						Hose nipple					
				 
							
					
						MRC:
						An indication of whether or not an integral safety device is included.AHZU
					 
					
						Integral Relief Valve:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of the type of meter.ANTH
					 
					
						Meter Type:
					
					
						Float					
				 
							
					
						MRC:
						Indicates the design type of the item.APGF
					 
					
						Design Type:
					
					
						Case					
				 
							
					
						MRC:
						The number of scales on the item.APSJ
					 
					
						Scale Quantity:
					
					
						4					
				 
							
					
						MRC:
						The structural characteristic of the item.ARQS
					 
					
						Construction:
					
					
						Inclosed w/sight window					
				 
							
					
						MRC:
						A narrative description of the type of outlet connection.ARTH
					 
					
						Outlet Connection Type:
					
					
						Hose nipple					
				 
							
					
						MRC:
						The number of floats provided.AWAE
					 
					
						Float Quantity:
					
					
						1					
				 
							
					
						MRC:
						An indication of whether or not a carrying handle is included.AXQG
					 
					
						Carrying Handle:
					
					
						Not included					
				 
							
					
						MRC:
						The minimum and maximum markings on a dial scale.BHBY
					 
					
						Dial Scale Marking Range:
					
					
						-0.1 to 30.0					
				 
							
					
						MRC:
						An indication of whether or not a base(s) is included.BHJT
					 
					
						Base:
					
					
						Included					
				 
							
					
						MRC:
						Indicates the type of float used.BHSQ
					 
					
						Float Type:
					
					
						Free					
				 
							
					
						MRC:
						The element,compound,or mixture of which the float is fabricated,excluding any surface treatment.BJDM
					 
					
						Float Material:
					
					
						Plastic					
				 
							
					
						MRC:
						An indication of whether or not an integral heat source is included.BNHN
					 
					
						Integral Heat Source:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of whether or not a dial scale reference pointer is included.CPZK
					 
					
						Dial Scale Reference Pointer:
					
					
						Included					
				 
							
					
						MRC:
						An indication of whether or not a spinning float is included.CPZM
					 
					
						Spinning Float:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of whether or not an integral pulsation dampener is included.CPZN
					 
					
						Integral Pulsation Dampener:
					
					
						Not included					
				 
							
					
						MRC:
						The inlet connection position for which the item is designed.CPZP
					 
					
						Inlet Connection Position For Which Designed:
					
					
						Vertical					
				 
							
					
						MRC:
						The outlet connection position for which the item is designed.CPZR
					 
					
						Outlet Connection Position For Which Designed:
					
					
						Horizontal					
				 
							
					
						MRC:
						Indicates the type of outlet connection device provided.CPZS
					 
					
						Outlet Connection Device Type:
					
					
						Stationary					
				 
							
					
						MRC:
						An indication of whether or not an alarm signal is included.CPZT
					 
					
						Alarm Signal:
					
					
						Not included					
				 
							
					
						MRC:
						Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
					 
					
						Special Features:
					
					
						Flow range:  0.2 through 30 lpm,  acrylic body,  accuracy is +/- 3 percent,  includes:  hose barb,  tygon tubing and luer adapter.Measure airflow in air sampling application.