Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Anes app gas: w/o2 monitor n2o o2 & volatile liq 4 cy cap port
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Gas Anesthesia Apparatus
MRC:
An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
Carrying Case:
Provided
MRC:
An indication of whether or not the item is furnished with a handle.AFYG
Handle:
Furnished
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Adapter, elbow 2; adapter, tee 1; gasket 10; harness, head 1; key, socket head screw 1; mask, oronasal 5; rebreathing bag 2; tubing, inhaler 3; wrench, open end 2; wrench, tee-handle 1
MRC:
An indication of whether or not a locking device is included.AMDA
Locking Device:
Not included
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Portable
MRC:
The number of cylinders accommodated in the stand.CLQQ
Err Default:
Err default
MRC:
The means by which the gas head is mounted to the stand.CLQW
Err Default:
Err default
MRC:
The number of flowmeters provided on the item.CLQZ
Err Default:
Err default
MRC:
The number of carbon dioxide absorption chambers provided.CLRB
Err Default:
Err default
MRC:
An indication of whether or not a manometer is included.CLRG
Err Default:
Err default
MRC:
The measured weight of the exterior container.ECWT
Exterior Container Weight:
108.00 pounds
MRC:
A measurement of volume taken by multiplying the length by the width by the height of the exterior container and rendered in cubic units.EXME
Exterior Container Cubic Measure:
6.200 cubic feet
MRC:
The number of units of issue placed inside the exterior container.EXQT
Exterior Container Quantity:
1
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Lfor open, semi closed, or closed method; for use with size d or e flush valve gas cylinder or large size gas cylinder; field; with cartridge-type carbon dioxide absorber and oxygen flush valve; with integral vaporizer, pressure regulators, and flexible hoses with end connection; supplied without cylinders and oxygen monitors; forr carbon dioxide absorber absorber cartridge, order 6505-00-782-6484; for oxygen monitor, 6515-01-130-1379, army and air force requires the use of an in-line oxygen-monitor; for replacement parts; bag, rebreathing, 6515-01-030-8636; head hardness; 6515-00-386-9708, mask oronasal, 6515-01-033-3693 and 6515-01-033-3695; tube, inhaler, 6515-00-302-1500; nitrous oxide, oxygen, and volatile liquid anesthetics
MRC:
A measurement of volume taken by multiplying the length by the width by the height of the unit of issue and rendered in cubic units.SUCB
Unit Of Issue Cube:
6.200 cubic feet
MRC:
The measured weight of the actual container(s) or supporting device(s) which is in direct contact with the item and its contents.SUWT
Unit Of Issue Weight:
108.00 pounds