Teilenummer CR-18AU8.133330MHZ

Quartz Crystal Unit

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
cr-18au8.133330mhz
Entmilitarisierung:
Yes - DEMIL/MLI
Lagerfähigkeit:
Maßeinheit:
NIIN:
011494065
NSN
Nationale Bestandsnummer:
5955-01-149-4065 5955011494065
TXT
Beschreibung:
Quartz Crystal Unit
INC
INC
Artikelname-Code:
00196
INC
COM
Beachtung:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 0.998 inches and 1.023 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
Between 0.223 inches and 0.248 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.757 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.775 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.725 inches
MRC:
A measurement of the smallest dimension of a body,in distinction from length or width.ADPR
Body Thickness:
0.317 inches
MRC:
An overall measurement of the smallest dimension of an item,in distinction from length or width.ADUM
Overall Thickness:
0.352 inches
MRC:
The length of a straight line which passes through the center of a terminal,and terminates at the circumference.AEBT
Terminal Diameter:
Between 0.048 inches and 0.052 inches
MRC:
The mode of frequency at which the device is designed to operate.AEHC
Mode Of Oscillation:
Fundamental
MRC:
The condition existing when the frequency or vibration equals the natural frequency.AEHD
Circuit Resonance:
Antiresonance
MRC:
The amount of electrical capacitance under a load condition,required for normal operation in a circuit,expressed in picofarads.AEHE
Load Capacitance In Picofarads:
Between 31.5 and 32.5
MRC:
The total static capacitance of the item when measured across the terminals,expressed in picofarads.AEHF
Shunt Capacitance In Picofarads:
7.0
MRC:
The frequency at which the item is designed to operate under specified conditions.AEHG
Specified Frequency:
8.13333 megahertz
MRC:
The element,compound,or mixture of which the holder cover is fabricated.AEHS
Holder Cover Material:
Metal
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+105.0 degrees celsius
MRC:
None.CQBK
Center To Center Distance Between Terminals:
0.478 mils and 0.497 centimeters
MRC:
The drive level at which the item is designed to operate.CQYL
Drive Level Rating:
Between 8.0 milliwatts and 12.0 milliwatts
MRC:
The permissible frequency deviation within the operating temperature range,expressed in percent.CRFX
Frequency Tolerance For Operating Tempurature In Percent:
-0.005/+0.005
MRC:
The equivalent (effective) resistance for which the item is rated,expressed in ohms.CRMP
Equivalent Resistance Value In Ohms:
24.0
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-c-3098 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-c-3098/3 government specification