Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Sensitive Switch				
			 
			
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Hole mounted					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						4.710 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						1.730 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						2.720 inches 					
				 
							
					
						MRC:
						The measurement of the distance that the actuator protrudes from the body.AFGK
					 
					
						Actuator Length:
					
					
						Between 1.380 inches and 4.330 inches 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
					 
					
						Actuator Style:
					
					
						Roller arm					
				 
							
					
					
						Actuator Height:
					
					
						1.150 inches 					
				 
							
					
					
						Actuator Roller Diameter:
					
					
						0.630 inches 					
				 
							
					
					
						Actuator Roller Width:
					
					
						0.220 inches 					
				 
							
					
					
						Housing Height:
					
					
						1.730 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the housing,in distinction from width.AFWD
					 
					
						Housing Length:
					
					
						3.260 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of a housing,in distinction from thickness.AFWE
					 
					
						Housing Width:
					
					
						1.570 inches 					
				 
							
					
					
						Center To Center Distance Between Housing Mounting Facilities Parallel To Length:
					
					
						2.360 inches 					
				 
							
					
					
						Center To Center Distance Between Housing Mounting Facilities Parallel To Width:
					
					
						1.180 inches 					
				 
							
					
						MRC:
						The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
					 
					
						Maximum Voltage Rating In Volts:
					
					
						240.0 dc and 600.0 ac					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						1730-01-209-0154 maintenance platform, aircraft					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Base and threaded hole					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Electrical access port					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.190 inches					
				 
							
					
						MRC:
						The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
					 
					
						Nonpile-up Contact Arrangement:
					
					
						1 pole,  double throw,  one position momentary single switch unit					
				 
							
					
						MRC:
						The amount of force required to actuate the switch.CSJN
					 
					
						Switch Actuating Force:
					
					
						25.0 inch-ounces 					
				 
							
					
						MRC:
						The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
					 
					
						Contact Load Current Rating At Maximum Rated Voltage:
					
					
						0.550 amperes resistive dc and 1.200 amperes resistive ac					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					
						Unc					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						3 screw