Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
crr50-580-gr
Informationen zum Teil
Includes two cga 580 fittings
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Fluid Pressure Regulating Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Steel, corrosion resisting, qq-s-763, class 302, 303, 304, 305, 310, or 316
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight thru
MRC:
Items furnished as accessories which are not specified elsewhere.ABFF
Furnished Items:
Inlet pressure gage and outlet pressure gage and automatic relief valve
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Any acceptable
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
First End Thread Size And Series/type Designator:
1/4-18 nptf
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Diaphragm
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Steel, corrosion resisting
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The means other than the end connection/s/ by which the item may be mounted.ADZJ
Mounting Facility:
Panel
MRC:
The minimum to maximum limits of outlet pressure of the item.AEVA
Outlet Pressure Range:
+0.0/+40.0 pounds per square inch
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Manual single stage
MRC:
The means used to manually adjust the item.AEVP
Manual Control Method:
Tee handle
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
3000.0 pounds per square inch