Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Degreaser
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
8.000 inches
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
16.000 inches
MRC:
A measurement of the longest inside dimension of an item,in distinction from width.ADJU
Inside Length:
19.500 inches
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
8.000 inches
MRC:
The electrical voltage value for which the generator is rated.ALSP
Generator Voltage Rating:
12.0
MRC:
The number of alternating current phases of the generator.ALSR
Generator Phase:
Single
MRC:
The cycles per second (hertz) of the generator alternating current.ALSS
Generator Frequency Rating:
60.0
MRC:
An indication of whether or not the item is portable.APCB
Portability:
Portable
MRC:
Indicates the design type of the item.APGF
Design Type:
Ultrasonic
MRC:
The rated horsepower of the electric motor.ASHK
Electric Motor Horsepower Rating:
0.2
MRC:
Indicates the type of current of the generator,whether alternating,direct,or both.BCPD
Generator Current Type:
Ac
MRC:
An indication of whether or not an electric motor is included.BMWX
Electric Motor:
Included
MRC:
Indicates the type of current for the electric motor.BRWR
Electric Motor Current Type:
Ac
MRC:
Indicates the capacity of the tank.BSSM
Tank Capacity:
Not rated
MRC:
The amount of operating voltage of the electric motor,expressed in volts.BWQL
Electric Motor Operating Voltage In Volts:
120.0
MRC:
The cycles per second /hertz/ of the alternating current for which the electric motor is rated.BWQM
Electric Motor Operating Frequency In Hertz:
60.0
MRC:
The number of alternating current phases for which the electric motor is designed.BWWN
Electric Motor Phase:
Single
MRC:
The value of electrical input power for which the generator is rated.BWWR
Err Default:
Err default
MRC:
The value of electrical output power for which the generator is rated.BWWS
Generator Output Power Rating:
2000.000 watts
MRC:
The range of complete cyclic changes,per unit of time,for which the generator output is rated.BWWT
Err Default:
Err default
MRC:
The means by which the generator is cooled.BWWW
Generator Cooling Method:
Any acceptable
MRC:
The distance measured in a straight line from the bottom to the top of the generator.BWWX
Err Default:
Err default
MRC:
An overall measurement taken at right angles to the length of the generator,in distinction from thickness.BWWY
Err Default:
Err default
MRC:
An overall measurement between specified points of the generator,in distinction from height.BWWZ
Err Default:
Err default
MRC:
An indication of whether or not a solvent reconditioner is included.BWXD
Solvent Reconditioner:
Included
MRC:
An indication of whether or not a spray cleaning provision is provided.BWXF
Spray Cleaning Provision:
Provided
MRC:
An indication of whether or not an auxiliary solvent supply is included.BWXG
Auxiliary Solvent Supply:
Included