Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Power Operated Drum Winch				
			 
			
										
					
						MRC:
						The number of prime movers incorporated in the unit.AAXH
					 
					
						Prime Mover Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of current whether alternating,direct,or both.ACDC
					 
					
						Current Type:
					
					
						Dc					
				 
							
					
						MRC:
						The name and number of those parts furnished with the item of supply that have not been specified elsewhere.ACSY
					 
					
						Furnished Items And Quantity:
					
					
						1 motor controller					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Waterproof					
				 
							
					
						MRC:
						Indicates the type of prime mover included with the unit.AKDJ
					 
					
						Prime Mover Type:
					
					
						Electric motor					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The working period under which the item was designed to operate.AKPS
					 
					
						Duty Cycle:
					
					
						Intermittent					
				 
							
					
						MRC:
						The means used to operate the item.APHE
					 
					
						Operation Method:
					
					
						Power					
				 
							
					
						MRC:
						The distance between flanges on the drum,and the location on the item.ATWD
					 
					
						Drum Flange To Flange Distance And Location:
					
					
						16.000 inches  first drum and 16.000 inches  second drum					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the drum,and terminates at the circumference,and its location on the item.ATWE
					 
					
						Drum Diameter And Location:
					
					
						18.000 inches  first drum and 18.000 inches  second drum					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the drum flange,and terminates at the circumference,and its location on the item.ATWF
					 
					
						Drum Flange Diameter And Location:
					
					
						26.000 inches  first drum and 26.000 inches  second drum					
				 
							
					
						MRC:
						An indication of the capstan spool/s/ mounting position.ATWG
					 
					
						Capstan Spool Mounting Position:
					
					
						Horizontal					
				 
							
					
						MRC:
						The design of the capstan spool surface.ATWJ
					 
					
						Capstan Spool Surface Design:
					
					
						Plain					
				 
							
					
						MRC:
						The number of capstan spools included.ATWK
					 
					
						Capstan Spool Quantity:
					
					
						1					
				 
							
					
						MRC:
						The total load the item is capable of moving at selected speeds and the drum location.ATWN
					 
					
						Load Limit At Selected Speed And Drum Location:
					
					
						1850.0 pounds single speed first drum and 1850.0 pounds single speed second drum					
				 
							
					
						MRC:
						The distance that the item will move per minute,per specific measurement scale.ATWP
					 
					
						Travel Rate Per Minute:
					
					
						100.0 feet					
				 
							
					
						MRC:
						The power required to start and operate the item at rated capacity.ATYG
					 
					
						Power Requirement Rating:
					
					
						20.00 horsepower					
				 
							
					
						MRC:
						The design on the drum surface.ATYH
					 
					
						Drum Surface Design:
					
					
						Plain					
				 
							
					
					
						Largest Diameter And Location:
					
					
						17.750 inches  first spool					
				 
							
					
					
						Overall Length And Location:
					
					
						15.000 inches  first spool					
				 
							
					
						MRC:
						The means of cooling used to maintain the required operating temperature of the item.BFMF
					 
					
						Cooling Method:
					
					
						Any acceptable					
				 
							
					
						MRC:
						The total electrical voltage.ELEC
					 
					
						Voltage In Volts:
					
					
						115.0