Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Glass Dielectric Fixed Capacitor
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
1.120 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.344 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.172 inches
MRC:
Direct current resistance between two conductors that are separated by an insulating material,measured at the maximum operating temperature of the item.CQBF
Insulation Resistance At Maximum Operating Temp:
10000.0 megohms
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Unable To Decode:
Unable to decode and unable to decode
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Nonderated Operating Temp:
Between -55.0 degrees celsius and 125.0 degrees celsius
MRC:
The constant that represents the proportionate change in capacitance per section caused by a change in temperature,expressed in parts per million per degree celsius.CQLZ
Tempurature Coefficient Of Capacitance Per Section In Ppm Per Deg Celsius:
140.0 single section
MRC:
The limits of permissible deviation of the temperature coefficient per section from the rated value,expressed in parts per million per degree celsius.CRHD
Tolerance Of Tempurature Coefficient Per Section In Ppm Per Deg Celsius:
-25.0 to 25.0 single section
MRC:
The chemical compound or mechanical mixture properties of which the case is fabricated.CWJK
Case Material:
Glass
MRC:
Direct current resistance between two conductors that are separated by an insulating material,measured at reference temperature.CWPK
Insulation Resistance At Reference Temp:
100000.0 megohms
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 uninsulated wire lead