Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Flange type:  cpr159f modified w/cres inserts,  cpr159g modified w/stainless steel captive hardware 1.25 lg socket head cap screw;  wr159 heavy wall (0.125 in. Thk) waveguide;  1.0mw peak power handling,  1.0kw avg. Power handling;  operating temp:  -40/+52 degrees c,  storage temp:  -40/+68 degrees c.
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Waveguide Assembly				
			 
			
							
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
					 
					
						Cross Sectional Shape:
					
					
						Internal,  rectangular external,  rectangular					
				 
							
					
						MRC:
						A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
					 
					
						Thread Class:
					
					
						2a second flange all connection facilities					
				 
							
					
						MRC:
						A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
					 
					
						Thread Class:
					
					
						2b first flange all connection facilities					
				 
							
					
						MRC:
						The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
					 
					
						Thread Direction:
					
					
						Right-hand all flanges all connection facilities					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Next assembly 200425797 used on 200532017					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
					 
					
						Tubing Wall Construction Style:
					
					
						Seamless single tubing segment					
				 
							
					
						MRC:
						The number of flanges provided with the item.AHSF
					 
					
						Flange Quantity:
					
					
						2					
				 
							
					
						MRC:
						The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
					 
					
						Voltage Standing Wave Ratio:
					
					
						1.50					
				 
							
					
						MRC:
						The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
					 
					
						Insertion Loss In Decibels:
					
					
						0.30					
				 
							
					
						MRC:
						The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
					 
					
						Thready Qty Per Inch (tpi):
					
					
						20 all flanges all connection facilities					
				 
							
					
						MRC:
						The maximum pressure at which the item is rated for operation.CQGM
					 
					
						Maximum Operating Pressure:
					
					
						40.0 pounds per square inch gage					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.250 inches all flanges all connection facilities					
				 
							
					
					
						Waveguide Longer Offset Distance:
					
					
						59.000 inches 					
				 
							
					
						MRC:
						The type and number of facilities by which the flange is connected.CSQT
					 
					
						Flange Connecting Facility And Quantity:
					
					
						8 threaded hole all flanges all connection facilities					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
					 
					
						Flange Style:
					
					
						Contact type first flange					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
					 
					
						Flange Style:
					
					
						Cover type second flange					
				 
							
					
					
						Waveguide Offset Distance:
					
					
						7.000 inches 					
				 
							
					
						MRC:
						The frequency at which the item is designed to operate under specified conditions.CZKN
					 
					
						Specified Frequency:
					
					
						Between 4.9 gigahertz and 6.75 gigahertz 					
				 
							
					
						MRC:
						Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
					 
					
						Flexibility:
					
					
						Flexible single tubing segment					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Copper alloy all flange					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Copper single tubing segment					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Bend type					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					