Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
d1855pc1t040
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Exhaust Muffler
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
81.688 inches
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Flange
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Unthreaded
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Flange 1st outlet
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Unthreaded single inlet
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
39.688 inches
MRC:
The length of a straight line which passes through the center of the outlet,and terminates at the inside circumference.AJLW
Outlet Inside Diameter:
13.625 inches
MRC:
Indicates the design type of the item.APGF
Design Type:
Wet
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Water
MRC:
The basic design of the muffler.ARND
Muffler Design:
Straight through
MRC:
The physical configuration of the body.ARNG
Body Shape:
Round
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
Horizontal
MRC:
The location of the inlet.ARNJ
Inlet Location:
Located 24-1/2 in. From center to flat end of muffler on left side looking aft
MRC:
A measurement of the longest dimension of the inlet projection,in distinction from width.ARNK
Inlet Projection Length:
24.000 inches
MRC:
The physical configuration of the inlet flange.ARNL
Inlet Flange Shape:
Round
MRC:
The type and number of inlet flange mounting provisions provided.ARNM
Inlet Flange Mounting Provision And Quantity:
19 holes
MRC:
The length of a straight line passing through the center of an inlet flange mounting hole,and terminating at the circumference.ARNN
Inlet Flange Mounting Hole Diameter:
1.000 inches
MRC:
The spacing of the inlet flange mounting provision.ARNT
Inlet Flange Mounting Provision Spacing:
17-3/8 in. Diameter bolt circle
MRC:
The length of a straight line which passes through the center of the inlet,with terminated points on the outside circumference.ARSQ
Inlet Outside Diameter:
19.125 inches
MRC:
The length of a straight line which passes through the center of the inlet,with terminated points on the inside circumference.ARTE
Inlet Inside Diameter:
13.625 inches
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Flange
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Unthreaded
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Flange 1st outlet
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Unthreaded single inlet
MRC:
The location of the outlet.ARTJ
Outlet Location:
34-9/16 in. From center line of inlet to center line of outlet on left side looking aft
MRC:
A measurement of the longest dimension of the outlet projection,in distinction from width.ARTK
Outlet Projection Length:
24.000 inches
MRC:
The physical configuration of the outlet flange.ARTL
Outlet Flange Shape:
Round
MRC:
Indicates the type and number of outlet flange mounting provisions provided.ARTM
Outlet Flange Mounting Provision And Quantity:
19 studs
MRC:
The length of a straight line passing through the center of an outlet flange mounting hole,and terminating at the circumference.ARTN
Outlet Flange Mounting Hole Diameter:
1.000 inches
MRC:
A measurement of the spacing of the outlet flange mounting provision.ARTT
Outlet Flange Mounting Provision Spacing:
17-3/8 in. Diameter bolt circle
MRC:
The length of a straight line which passes through the center of the outlet,with terminated points on the outside circumference.ARWA
Outlet Outside Diameter:
19.125 inches
MRC:
A narrative description of the type of water inlet connection.ARWE
Err Default:
Err default
MRC:
A narrative description of the type of water inlet connection.ARWE
Water Inlet Connection Type:
Unthreaded
MRC:
The location of the water inlet.ARWF
Err Default:
Err default
MRC:
The location of the water inlet.ARWF
Water Inlet Location:
Center located 11 in. From center line of exhaust inlet
MRC:
A measurement of the longest dimension of the water inlet projection,in distinction from width.ARWG
Err Default:
Err default
MRC:
A measurement of the longest dimension of the water inlet projection,in distinction from width.ARWG
Water Inlet Projection Length:
24.063 inches
MRC:
The physical configuration of the water inlet flange.ARWH
Err Default:
Err default
MRC:
The physical configuration of the water inlet flange.ARWH
Water Inlet Flange Shape:
Round
MRC:
A measurement of the spacing of the water inlet flange bolt holes.ARWJ
Err Default:
Err default
MRC:
A measurement of the spacing of the water inlet flange bolt holes.ARWJ
Water Inlet Flange Bolt Hole Spacing:
9-1/2 in. Diameter bolt circle
MRC:
The number of water inlet flange bolt holes provided.ARWK
Err Default:
Err default
MRC:
The number of water inlet flange bolt holes provided.ARWK
Water Inlet Flange Bolt Hole Quantity:
8
MRC:
The length of a straight line which passes through the center of the water inlet flange bolt hole,and terminates at the circumference.ARWL
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the water inlet flange bolt hole,and terminates at the circumference.ARWL
Water Inlet Flange Bolt Hole Diameter:
0.875 inches
MRC:
The length of a straight line which passes through the center of the water inlet,and terminates at the outside circumference.ARXC
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the water inlet,and terminates at the outside circumference.ARXC
Water Inlet Outside Diameter:
11.000 inches
MRC:
The length of a straight line which passes through the center of the water inlet,with terminated points on the inside circumference.ARXD
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the water inlet,with terminated points on the inside circumference.ARXD
Water Inlet Inside Diameter:
6.000 inches
MRC:
A narrative description of the type of water outlet connection.ARXE
Err Default:
Err default
MRC:
A narrative description of the type of water outlet connection.ARXE
Water Outlet Connection Type:
Flange
MRC:
The number of water outlets furnished with the item.ARXF
Err Default:
Err default
MRC:
The number of water outlets furnished with the item.ARXF
Water Outlet Quantity:
1
MRC:
The location of the water outlet.ARXG
Err Default:
Err default
MRC:
The location of the water outlet.ARXG
Water Outlet Location:
Near exhaust outlet toward center of muffler
MRC:
A measurement of the longest dimension of the water outlet projection,in distinction from width.ARXH
Err Default:
Err default
MRC:
A measurement of the longest dimension of the water outlet projection,in distinction from width.ARXH
Water Outlet Projection Length:
24.063 inches
MRC:
The physical configuration of the water outlet flange.ARXJ
Err Default:
Err default
MRC:
The physical configuration of the water outlet flange.ARXJ
Water Outlet Flange Shape:
Square
MRC:
The length of a straight line passing through the center of the water outlet flange bolt circle,with terminated points at the circumference.ARXK
Err Default:
Err default
MRC:
The length of a straight line passing through the center of the water outlet flange bolt circle,with terminated points at the circumference.ARXK
Water Outlet Flange Bolt Circle Diameter:
9.500 inches
MRC:
The number of bolt holes included on the water outlet flange.ARXL
Err Default:
Err default
MRC:
The number of bolt holes included on the water outlet flange.ARXL
Water Outlet Flange Bolt Hole Quantity:
8
MRC:
The length of a straight line passing through the center of a water outlet flange bolt hole,and terminating at the circumference.ARXM
Err Default:
Err default
MRC:
The length of a straight line passing through the center of a water outlet flange bolt hole,and terminating at the circumference.ARXM
Water Outlet Flange Bolt Hole Diameter:
0.875 inches
MRC:
The length of a straight line which passes through the center of the water outlet,with terminated points on the outside circumfernce.ARXW
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the water outlet,with terminated points on the outside circumfernce.ARXW
Water Outlet Outside Diameter:
11.000 inches
MRC:
The length of a straight line which passes through the center of the water outlet,and terminates at the inside circumference.ARXX
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the water outlet,and terminates at the inside circumference.ARXX
Water Outlet Inside Diameter:
6.000 inches
MRC:
The number of hand holes provided on the item.ARYB
Err Default:
Err default
MRC:
The number of hand holes provided on the item.ARYB
Hand Hole Quantity:
2
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Nickel-copper, mil-n-894 or steel, mil-s-853
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Nickel-copper, mil-n-894 or steel, mil-s-853
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Porcelain enamel
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Port