Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Canadien standard
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Pressure Switch				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						4.343 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						4.562 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						3.500 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						2.187 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.203 inches 					
				 
							
					
						MRC:
						The distance between mounting facility centers.AEJN
					 
					
						Distance Between Mounting Facility Centers:
					
					
						2.250 inches 					
				 
							
					
						MRC:
						The general classification of a pressure switch based on the reference method used to measure the sensed pressure.AJZC
					 
					
						Pressure Switch Type:
					
					
						Gage					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Bracket and unthreaded hole					
				 
							
					
						MRC:
						An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
					 
					
						Contact Action Stimulus:
					
					
						Decrease					
				 
							
					
						MRC:
						The maximum pressure that an item will withstand without resulting in any permanent changes in the structural,mechanical,or electrical characteristics.CQJB
					 
					
						Proof Pressure:
					
					
						60.00 pounds per square inch					
				 
							
					
						MRC:
						The general configuration and relative position of the facilities provided for mounting the item.CQYJ
					 
					
						Mounting Facility Pattern:
					
					
						Two position in-line					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						3.0 amperes resistive load first voltage					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						10.0 amperes resistive load second voltage					
				 
							
					
						MRC:
						The adjustability of the contact.CTYC
					 
					
						Contact Adjustability:
					
					
						Actuation point adjustable and  deactuation point adjustable					
				 
							
					
						MRC:
						The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
					 
					
						Contact Adjustment Range:
					
					
						+0.40/+17.74 actuation point pounds per square inch and +0.66/+18.00 deactuation point pounds per square inch					
				 
							
					
						MRC:
						Indicates the type of device provided for manual adjustment of the contact(s).CTYS
					 
					
						Contact Adjustment Type:
					
					
						External actuation point screw and  external deactuation point screw					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						125.0 ac at sea level second voltage					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						480.0 ac at sea level first voltage					
				 
							
					
						MRC:
						The type of media for which the item is designed.MEDA
					 
					
						Media For Which Designed:
					
					
						Liquid					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Rectangular w/bracket