Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
With built-in elapse time meter
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Alternating Current Motor
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
10.080 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
11.236 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
11.330 inches
MRC:
The number of splines on or in the item.ABSA
Spline Quantity:
12 single end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.6640 inches single end
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Counterclockwise single end
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Totally enclosed
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Induction-squirrel cage
MRC:
The means of attaching the item.AXGY
Mounting Method:
Fixed base
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Separately ventilated
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Commercial
MRC:
The distance between the center of the shaft to the mounting surface.CWDM
Shaft Center To Mounting Surface Distance:
4.030 inches single end
MRC:
The nominal center to center distance between the mounting facilities parallel to the length.CWDT
Center To Center Distance Between Mounting Facilities Parallel To Length:
4.140 inches
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
5.120 inches
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A14 single style single end
MRC:
The number of alternating current phases.FAAZ
Phase:
Three input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0 input