					Beschreibung:
				
				
					Hydraulic System Comp Test Stand				
			 
			
										
					
						MRC:
						The amount of hydraulic fluid required to operate the item.AAYJ
					 
					
						Hydraulic Fluid Flow Rate:
					
					
						40.0 gallons per minute					
				 
							
					
						MRC:
						Indicates the type of current whether alternating,direct,or both.ACDC
					 
					
						Current Type:
					
					
						Ac					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Titan engine age.					
				 
							
					
						MRC:
						Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
					 
					
						Drive Type:
					
					
						Shaft					
				 
							
					
						MRC:
						Indicates the designed use of the item.ALBY
					 
					
						Usage Design:
					
					
						Individual hydraulic units					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Fixed					
				 
							
					
						MRC:
						An indication of the rated horsepower of the item.ANCY
					 
					
						Horsepower Rating:
					
					
						7.5					
				 
							
					
						MRC:
						The source of power which drives the item.ATJK
					 
					
						Power Source:
					
					
						Electric motor					
				 
							
					
						MRC:
						The maximum speed at which the item is designed to operate,expressed in revolutions per minute.ATPR
					 
					
						Maximum Speed Rating In Rpm:
					
					
						5000.0					
				 
							
					
						MRC:
						An indication of whether or not an accumulator is included.AYJM
					 
					
						Accumulator:
					
					
						Not included					
				 
							
					
						MRC:
						The pressure at which an item is designed to operate.BGST
					 
					
						Pressure Rating:
					
					
						350.0 pounds per square inch 					
				 
							
					
						MRC:
						The maximum pressure at which the item is designed to operate.BJDW
					 
					
						Maximum Operating Pressure:
					
					
						350.0 pounds per square inch					
				 
							
					
						MRC:
						An indication of whether or not a design feature for testing engine driven hydraulic pumps is included.CGYK
					 
					
						Engine Driven Hydraulic Pump Testing Design Feature:
					
					
						Included					
				 
							
					
						MRC:
						The rated flow capacity of the item.CGYL
					 
					
						Flow Capacity Rating:
					
					
						40.0 gallons per minute					
				 
							
					
						MRC:
						An indication of whether or not a pressure manifold subcircuit(s) is included.CGYM
					 
					
						Pressure Manifold Subcircuit:
					
					
						Included					
				 
							
					
						MRC:
						The number of subcircuits provided and the maximum operating pressure of each subcircuit.CHGN
					 
					
						Subcircuit Quantity And Maximum Operating Pressure:
					
					
						Two 350 and 40 psi					
				 
							
					
						MRC:
						An indication of whether or not a filtering system is included.CHGQ
					 
					
						Filtering System:
					
					
						Included					
				 
							
					
						MRC:
						An indication of whether or not a pressure and suction hose are included.CHGR
					 
					
						Pressure/suction Hose:
					
					
						Not included					
				 
							
					
						MRC:
						The total electrical voltage.ELEC
					 
					
						Voltage In Volts:
					
					
						220.0					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Three					
				 
							
					
						MRC:
						The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
					 
					
						Functional Classification:
					
					
						Gg-7.3					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						60.0					
				 
							
					
						MRC:
						Literature and references available for information pertaining to the item.RDAL
					 
					
						Reference Data And Literature:
					
					
						T.O. 33d4-7-4-4