Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Safety Relief Valve
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
3a 1st end
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand 1st end
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
Indicates the type of housing on the item that accommodates the stem packing or spring.ADSR
Bonnet Type:
Inside spring
MRC:
The means by which the bonnet is attached to the item.ADST
Bonnet Attachment Method:
Integral
MRC:
The means of closing the item when inlet pressure decreases.ADSU
Disk Loading Method:
Spring
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
400.0 degrees fahrenheit single response
MRC:
The minimum temperature at which the item is designed to operate.AEQJ
Minimum Operating Temp:
-65.0 degrees fahrenheit
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
G46b plain (pipe) 1st end
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Plain (pipe) 1st end
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded external tube 1st end
MRC:
The minimum to maximum pressures at which the item may be set to open.CQCY
Adjustable Pressure Range:
+10.0/+30.0 pounds per square inch
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
200.0 pounds per square inch single response
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.437 inches 1st end
MRC:
The predetermined pressure at which the item is calibrated to open.CSDC
Opening Pressure Setting:
20.0 pounds per square inch
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
0.250 inches 1st end
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel comp 303 body
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel comp 303 flow control device and rubber silicone class q flow control device
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel comp 303 seat
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Fedstd66, aisi303/sae30303 federal standard single material response seat
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Fedstd66, aisi303/sae30303 federal standard 1st material response flow control device and ams3304 assn standard 2nd material response flow control device
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Fedstd66, aisi303/sae30303 federal standard single material response body
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Air 1st response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Carbon dioxide 2nd response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Helium 3rd response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Hydrogen 4th response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Nitrogen, gaseous 5th response
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Passivate
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight through w/baffle
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unjf 1st end
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.TMQY
Furnished Items And Quantity:
1 deflector cap