Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.800 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.500 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetically sealed
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
70000.0 feet
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
100.0 dc volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
3.0 dc kilovolts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
100.0 dc volts 2nd power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-54.0/+71.0 degrees celsius
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
2 1st power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
2 2nd power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage range 1st power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage range 2nd power output
MRC:
The means used to change alternating current voltage to direct current voltage.BHQN
Rectification Method:
Single phase full wave center tap
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
1.0 dc milliamperes 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
100.0 dc microamperes 1st power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 2nd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 1st power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Lug battery terminal 1st power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Lug battery terminal 2nd power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
50.0 dc milliamperes single operating power rqmt