Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
dcs3004em130ehtopt
Informationen zum Teil
Power supply
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.62 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.72 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.00 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Link 16 alask
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
225.0 ac volts and 115.0 ac volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
0.0 dc volts and 300.0 dc volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz and 63.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.0 to 50.0 degrees celsius
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
2 single power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment single power output
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
1.2 kilowatts single power output
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Digital ammeter and digital voltmeter
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.0 dc amperes and 4.0 dc amperes single power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
25.0 millivolts rms single power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel single power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
9.0 ac amperes and 18.0 ac amperes single operating power rqmt
MRC:
The time required for a power supply(ies) to reach the full operating potential for which it is rated,expressed in minutes.CWKM
Warm Up Time In Minutes:
30
MRC:
The power supply operational efficiency when connected to an alternate current power line.CWWY
Power Supply Efficiency Line:
85.0