Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Silent Motion Picture Projector
MRC:
The rated power that a lamp can safely consume or provide,measured in watts.AEWS
Lamp Wattage Rating In Watts:
300.0
MRC:
The voltage for which the lamp is rated for normal operation,expressed in volts.AEWX
Lamp Voltage Rating In Volts:
120.0
MRC:
The means established to identify the lamp by an industry standard number.AFAX
Lamp Industry Number:
Elh
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
Forward and reverse
MRC:
The type and amount of voltage for which the drive motor is designed.ATDC
Drive Motor Voltage Rating:
115.0 alternating current
MRC:
The projection material the item is designed to accommodate,and its type.AZYR
Projection Material And Type Accommodated:
Reel silent
MRC:
The amount of material the reel will accommodate.AZYX
Reel Capacity:
800.0 feet
MRC:
Indicates the type of projection lamp that provides illumination.AZYY
Projection Lamp Type:
Quartz halogen
MRC:
Designates the size of the lens opening through which the light passes.AZYZ
Lens Aperture Size:
1.8
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Forced air
MRC:
A measurement of the longest dimension from the center of a lens to the focal plane,in distinction from width.BKHF
Lens Focal Length:
2.00 inches
MRC:
A maximum measurement of the longest dimension of an item,in distinction from width.CHQP
Maximumlength:
435.0 millimeters
MRC:
The maximum measurement taken at right angles to the length of an item,in distinction from thickness.CHQQ
Maximumwidth:
425.0 millimeters
MRC:
The maximum distance measured in a straight line from the bottom to the top of an item.CHQR
Maximumheight:
245.0 millimeters
MRC:
The number of frames per second for which the item is rated.CTPH
Frame Rate Per Second:
0 variable and 18 variable
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0