Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
dpx2-67s67s33b02
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electrical Receptacle Connector
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight shape
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.953 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.109 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.000 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.AEBW
Center To Center Distance Between Mounting Facilities Parallel To Height:
2.781 inches
MRC:
The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.438 inches
Distance From Mounting Shoulder To Front Face:
0.766 inches
MRC:
Indicates the type of threaded device included on the item.AFQR
Threaded Device Type:
Mounting hole
MRC:
The number of mating ends provided with the item which are designed to accommodate another connector.AFQW
Mating End Quantity:
2
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the contact position/s/.AFQX
Contact Position Arrangement Style:
67 single mating end
MRC:
An indication of whether or not the contact(s) is removable.AFQZ
Contact Removability:
Nonremovable single mating end single contact grouping
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
13.0 single mating end 2nd contact grouping
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
13.0 single mating end 4th contact grouping
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
7.5 single mating end 1st contact grouping
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
7.5 single mating end 3rd contact grouping
MRC:
The means used to prevent mismating or cross plugging of contacts.AFRN
Polarization Method:
3 polarization posts
MRC:
Indicates the type of shell included on the item.AFRT
Shell Type:
Solid
MRC:
The chemical compound or mechanical mixture properties of which the contact is fabricated.CQTZ
Contact Material:
Copper alloy single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the insert is fabricated.CQZG
Insert Material:
Plastic diallyl phthalate single mating end
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Solder well single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the shell is fabricated.CSPT
Shell Material:
Aluminum
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the shell surface/s/ and cannot be wiped off.CSWM
Shell Surface Treatment:
Cadmium
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
3 single mating end 1st contact grouping
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
3 single mating end 3rd contact grouping
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
64 single mating end 2nd contact grouping
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
64 single mating end 4th contact grouping
MRC:
Indicates the type of contact(s) included with the item.CXCL
Included Contact Type:
Round socket single mating end single contact grouping