Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Sensitive Switch				
			 
			
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Hole mounted					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Length:
					
					
						1.000 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						1.940 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						0.687 inches 					
				 
							
					
						MRC:
						The number of actuators provided in the item for selection of switching positions.AFCG
					 
					
						Switch Actuator Quantity:
					
					
						1					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
					 
					
						Actuator Style:
					
					
						Round					
				 
							
					
						MRC:
						The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
					 
					
						Maximum Voltage Rating In Volts:
					
					
						250.0 ac and 125.0 dc					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
					 
					
						Nonpile-up Contact Arrangement:
					
					
						2 pole,  double throw,  one position momentary single switch unit					
				 
							
					
						MRC:
						The movement of the switch actuator.CXQQ
					 
					
						Actuator Movement:
					
					
						0.060 pretravel inches  and 0.688 overtravel inches  and 0.060 differential inches 					
				 
							
					
						MRC:
						The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
					 
					
						Contact Load Current Rating At Maximum Rated Voltage:
					
					
						0.300 amperes resistive dc and 10.000 amperes resistive ac					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						4 screw