Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.190 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.180 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.360 inches
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
96.0 ac pounds per hour dry single operating power rqmt and 264.0 ac pounds per hour with retaining chain single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
12.0 dc volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz single operating power rqmt and 63.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.0/+40.0 degrees celsius
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
30.0 watts single power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.5 dc amperes single power output