Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Centrifugal Pump Unit
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
7
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water, fresh
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
3600.0 revolutions per minute
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Vertical
MRC:
The design of a centrifugal pump as determined by the direction of media flow with respect to the axis of the shaft.AHZE
Centrifugal Pump Design:
Radial flow
MRC:
The number of impellers incorporated in the centrifugal pump.AHZF
Centrifugal Pump Impeller Quantity:
7
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
324.9
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Zzzy
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
265.000 horsepower
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
440.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Items that support a level i or subsafe critical system/component that has undergone quality assurance during the acquisition process and requires objective quality evidence (oqe) traceable to permanent marking on the materialas differentiated by prime mover type requirement, electric motor mfg gen