Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Delay Line				
			 
			
							
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Rectangular,  front connection					
				 
							
					
						MRC:
						An overall measurement between specified points of an item,in distinction from height.ABFY
					 
					
						Overall Depth:
					
					
						1.000 inches 					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						Not rated					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						4.000 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						3.375 inches 					
				 
							
					
						MRC:
						The number of individual sections included in the item.AFBH
					 
					
						Individual Section Quantity:
					
					
						1					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						Not rated					
				 
							
					
						MRC:
						The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
					 
					
						Material And Location:
					
					
						Steel,  corrosion resisting case					
				 
							
					
						MRC:
						The plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the item and its location.ANNR
					 
					
						Surface Treatment And Location:
					
					
						Tin plated case					
				 
							
					
						MRC:
						The total oppositon (resistive and reactive) which the item offers to the input flow of alternating current.ANSL
					 
					
						Input Impedance Rating:
					
					
						Not rated					
				 
							
					
						MRC:
						The total opposition (resistive and reactive) which the item offers to the output flow of alternating current.ANSR
					 
					
						Output Impedance Rating:
					
					
						500.000 ohms					
				 
							
					
						MRC:
						The differences between limiting frequencies of a frequency band.APQL
					 
					
						Frequency Bandwidth:
					
					
						Not rated					
				 
							
					
						MRC:
						A measurement between specified points on a body in distinction from height.ARBR
					 
					
						Body Depth:
					
					
						0.500 inches 					
				 
							
					
						MRC:
						The facility for mounting the item.AZGM
					 
					
						Mounting Facility:
					
					
						Pin					
				 
							
					
						MRC:
						The means by which the signal is delayed.BZWM
					 
					
						Signal Delay Method:
					
					
						Lumped constant					
				 
							
					
						MRC:
						The means used to vary the delay time of the item.CCDN
					 
					
						Delay Time Variation Method:
					
					
						Tapped					
				 
							
					
						MRC:
						The time delay of each section of an item.CCDQ
					 
					
						Section Delay Time:
					
					
						33.600 microseconds  single section					
				 
							
					
						MRC:
						The number of segments into which a section is divided.CCDR
					 
					
						Segment Quantity Per Section:
					
					
						21 single section					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						1.600 microseconds  single section 1st segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						11.200 microseconds  single section 7th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						12.800 microseconds  single section 8th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						14.400 microseconds  single section 9th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						16.000 microseconds  single section 10th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						17.600 microseconds  single section 11th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						19.200 microseconds  single section 12th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						20.800 microseconds  single section 13th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						22.400 microseconds  single section 14th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						24.000 microseconds  single section 15th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						25.600 microseconds  single section 16th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						27.200 microseconds  single section 17th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						28.800 microseconds  single section 18th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						3.200 microseconds  single section 2nd segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						30.400 microseconds  single section 19th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						32.000 microseconds  single section 20th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						33.600 microseconds  single section 21st segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						4.800 microseconds  single section 3rd segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						6.400 microseconds  single section 4th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						8.000 microseconds  single section 5th segment err-100					
				 
							
					
						MRC:
						The time delay of each segment.CCDS
					 
					
						Segment Delay Time:
					
					
						9.600 microseconds  single section 6th segment err-100					
				 
							
					
						MRC:
						The change in delay as a result of the temperature change per degree celsius.CCDT
					 
					
						Delay Time Variation Per Deg Celsius:
					
					
						Not rated					
				 
							
					
						MRC:
						The rated time required for the pulse to rise.CCDX
					 
					
						Pulse Rise Time Rating:
					
					
						0.84 microseconds					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.CCFF
					 
					
						Terminal Type And Quantity:
					
					
						23 pin