Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Refrigerated bath-circulator
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Constant Temperature Bath				
			 
			
							
										
					
						MRC:
						Indicates the type of mount utilized to support the item.AAXX
					 
					
						Mounting Type:
					
					
						Stand					
				 
							
					
						MRC:
						An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
					 
					
						Inside Width:
					
					
						220.0 millimeters 					
				 
							
					
						MRC:
						A measurement of the longest inside dimension of an item,in distinction from width.ADJU
					 
					
						Inside Length:
					
					
						140.0 millimeters 					
				 
							
					
						MRC:
						The number of covers furnished with the item.AEMW
					 
					
						Cover Quantity:
					
					
						1					
				 
							
					
						MRC:
						An inside measurement between specified points of an item,in distinction from height.AFEF
					 
					
						Inside Depth:
					
					
						150.0 millimeters 					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-22.0/+212.0 degrees fahrenheit					
				 
							
					
						MRC:
						An indication of whether or not an insulated feature is included.AHGR
					 
					
						Insulated Feature:
					
					
						Included					
				 
							
					
						MRC:
						Indicates the type of heating element current whether alternating,direct,or both.BBJZ
					 
					
						Heating Element Current Type:
					
					
						Ac					
				 
							
					
						MRC:
						The number of alternating current phases for which the heating element is designed.BBKB
					 
					
						Heating Element Phase:
					
					
						Single					
				 
							
					
						MRC:
						A measurement of the capacity of an item.BBLT
					 
					
						Capacity Rating:
					
					
						8.000 liters 					
				 
							
					
						MRC:
						The rated power the heating element can safely consume or provide,measured in watts.BBTG
					 
					
						Heating Element Wattage In Watts:
					
					
						1000.0					
				 
							
					
						MRC:
						Indicates the type of heating element provided.BDXJ
					 
					
						Heating Element Type:
					
					
						Electric immersion					
				 
							
					
						MRC:
						The number of heating elements provided on the item.BKGK
					 
					
						Heating Element Quantity:
					
					
						1					
				 
							
					
						MRC:
						The voltage value for which the heating element is rated.BKGR
					 
					
						Heating Element Voltage Rating:
					
					
						115.0 volts 					
				 
							
					
						MRC:
						The element,compound,or mixture of which the reservoir is fabricated,excluding any surface treatment.BNDF
					 
					
						Reservoir Material:
					
					
						Steel,  stainless					
				 
							
					
						MRC:
						An indication of whether or not the reservoir is removable.BNDG
					 
					
						Reservoir Removability:
					
					
						Nonremovable					
				 
							
					
						MRC:
						An indication of whether or not a test tube rack is included.BNDM
					 
					
						Test Tube Rack:
					
					
						Not included					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which the heating element is rated.BNDP
					 
					
						Heating Element Frequency Rating:
					
					
						60.0 hertz 					
				 
							
					
						MRC:
						An indication of whether or not an agitator is included.BNDQ
					 
					
						Agitator:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of whether or not a thermoregulator is included.BNDR
					 
					
						Thermoregulator:
					
					
						Included					
				 
							
					
						MRC:
						The range of accuracy for which the item is designed.BNDS
					 
					
						Accuracy Range:
					
					
						-0.1/+0.1 degrees fahrenheit					
				 
							
					
						MRC:
						An indication of the temperature regulating settings of the item.BNDT
					 
					
						Tempurature Regulating Settings:
					
					
						Adjustable					
				 
							
					
						MRC:
						An indication of whether or not cooling coils for below room temperature use are included.BNDW
					 
					
						Cooling Coils For Below Room Tempurature Use:
					
					
						Included					
				 
							
					
						MRC:
						An indication of whether or not a thermometer opening is provided.BNDX
					 
					
						Thermometer Opening:
					
					
						Not provided					
				 
							
					
						MRC:
						An indication of whether or not a pilot light is included.BNDY
					 
					
						Pilot Light:
					
					
						Not included					
				 
							
					
						MRC:
						Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
					 
					
						Special Features:
					
					
						 dimensions 15.7 inch wide,  26.5 inch high,  15.7 inch long					
				 
							
					
						MRC:
						The physical configuration of the item.SHPE
					 
					
						Shape:
					
					
						Rectangular