Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
fa1ke01056001
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
9.680 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.120 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.330 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/mpq-t3
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 1st alternate operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 2nd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
170.0 ac pounds per hour dry 2nd alternate operating power rqmt and 264.0 ac pounds per hour with retaining chain 2nd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
85.0 ac pounds per hour dry 1st alternate operating power rqmt and 132.0 ac pounds per hour with retaining chain 1st alternate operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
4.0 dc volts single power output and 5.5 dc volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 1st alternate operating power rqmt and 440.0 hertz 1st alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 2nd alternate operating power rqmt and 440.0 hertz 2nd alternate operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+71.0 degrees celsius
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
300.0 watts single power output
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Over voltage protector and remote error sensing capability and remote control and voltage adjustment
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
60.0 dc amperes single power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
5.0 millivolts peak single power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip single power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
4.6 ac amperes 1st alternate operating power rqmt and 6.0 ac amperes 1st alternate operating power rqmt
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
2.8 ac amperes 2nd alternate operating power rqmt and 3.6 ac amperes 2nd alternate operating power rqmt
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Terminal strip 1st alternate operating power rqmt
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Terminal strip 2nd alternate operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Single fan
MRC:
The power supply operational efficiency when connected to an alternate current power line.CWWY
Power Supply Efficiency Line:
77.0