Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						fae22015rb-1121					
 
					
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Item must comply with requirements of defense supply center columbus production standard no. Lo3498
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Circuit Breaker Box				
			 
			
										
					
						MRC:
						The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
					 
					
						Hazardous Locations/environmental Protection:
					
					
						Dusttight-nema type 5					
				 
							
					
						MRC:
						An overall measurement between specified points of an item,in distinction from height.ABFY
					 
					
						Overall Depth:
					
					
						4.140 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Width:
					
					
						1.500 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						5.998 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						4.468 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						2.937 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.AEBW
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Height:
					
					
						0.437 inches 					
				 
							
					
						MRC:
						A designation of the standard mounting facility arrangement provided.AESL
					 
					
						Standard Mounting Pattern Designator:
					
					
						4 point-rectangular					
				 
							
					
						MRC:
						Indicates the type of system in which the item is designed to be used.AGEJ
					 
					
						System For Which Designed:
					
					
						Three wire two phase					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Unthreaded hole					
				 
							
					
						MRC:
						The maximum current rating of the main line,expressed in amperes.BFYC
					 
					
						Main Line Maximum Current Rating In Amps:
					
					
						100.0					
				 
							
					
						MRC:
						The maximum alternating current voltage rating of the main line,expressed in volts.BFYD
					 
					
						Main Line Maximum Ac Voltage Rating In Volts:
					
					
						600.0					
				 
							
					
						MRC:
						Indicates the type and number of circuit breakers provided.BGJL
					 
					
						Circuit Breaker Type And Quantity:
					
					
						1 double pole					
				 
							
					
						MRC:
						The maximum electrical current which the circuit breaker will carry without interrupting the circuit,expressed in amperes.BGJM
					 
					
						Circuit Breaker Current Rating In Amps:
					
					
						15.0					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Cover					
				 
							
					
						MRC:
						The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
					 
					
						Criticality Code Justification:
					
					
						Zzzy					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Plastic					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Square,  surface mounting					
				 
							
					
						MRC:
						A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
					 
					
						Reference Number Differentiating Characteristics:
					
					
						Reference number differentiating material will be in accordance with naval inventory control point activity hx quality control. Manufacturing and testing specifications available at the dla icp