Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
X-ray apparatus radiogr-fluoroscopic 500ma 150pkv 230v 60hz ac
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Radiographic And X-ray Apparatus
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Stationary
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Motor
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Photo-timing circuit 1, compression device 1, multidiaphragm adjustable radiographic cone 1, control /separate kilovoltage/for fluoroscopic kilovo ltages 1, footrest 1, milliampere-second meter 1, spot-film change-over device 1, mylographic support patient 1, shoulder support 1
MRC:
Indicates the design type of the item.APGF
Design Type:
Stationary
MRC:
The means used to operate the item.APHE
Operation Method:
Automatic
MRC:
Indicates the type of control.AQZF
Control Type:
Vertical
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
1 and 1
MRC:
The value of electrical energy for which the item is rated.ARQE
Electric Power Rating:
65000.0 watts
MRC:
Indicates the type of tube provided.AWGH
Tube Type:
Double focus, rotating anode radiographic and double focus, rotating anode fluoroscopic
MRC:
Indicates the type of table provided.BNBB
Table Type:
Tilting
MRC:
Indicates the type of rectification provided.BPKZ
Rectification Type:
Full-wave
MRC:
Indicates the type of screen provided.CCFN
Err Default:
Err default
MRC:
The means of cooling used to maintain the required operating temperature of the tube.CLPG
Tube Cooling Method:
Air and air
MRC:
Indicates the type of mount utilized to support the tube.CLPH
Tube Mounting Type:
Tube stand and table
MRC:
Indicates the type of mount utilized to support the tube stand.CLPR
Tube Stand Mounting Type:
Overhead
MRC:
The minimum and maximum limits of tilt for which the item is designed.CLPT
Err Default:
Err default
MRC:
An indication of whether or not a bucky diaphragm is included.CLPW
Err Default:
Err default
MRC:
Indicates the type of radiographic timer provided.CLPX
Radiographic Timer Type:
Exposure
MRC:
Indicates the type of fluoroscopic timer provided.CLPY
Err Default:
Err default
MRC:
The means used for rectifying the transformer.CLQD
Transformer Rectification Method:
Electron tube
MRC:
The power output for which the transformer is rated.CLQF
Transformer Output Capacity:
500 ma at 125 kv peak, 300 ma at 150 kv peak
MRC:
A measurement of the longest dimension of the screen,in distinction from width.CMGN
Err Default:
Err default
MRC:
A measurement taken at right angles to the length of the screen,in distinction from thickness.CMGP
Err Default:
Err default
MRC:
Designates the size of the cassette.CMGQ
Err Default:
Err default
MRC:
Indicates the type of fluoroscopic screen provided.CTJL
Err Default:
Err default
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
190.0 and 250.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Requisition schould state whether high-speed incerts are required
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Requisition should state floor-loading capacity, ceiling strength and height, wall and floor construction (concrete, wood, etc), electrical supply and capacity, diagram of room indicating dimensions, compatability w/existing facilities, whether or not contractor installation service is required, and whether high-speed incerts are required