Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Pipeline Separator
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Flange
MRC:
The number of inlet bolt holes on the item.ACRL
Inlet Bolt Hole Quantity:
5
MRC:
The length of a straight line which passes through the center of an inlet bolt hole,and terminates at the circumference.ACRM
Inlet Bolt Hole Diameter:
0.688 inches
MRC:
The length of a straight line which passes through the center of an inlet bolt circle,and terminates at the circumference.ACRN
Inlet Bolt Circle Diameter:
4.063 inches
MRC:
The direction in which the fluid is passed through the item.ADNK
Flow Direction:
Up
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the largest circumference.AGQA
Largest Diameter:
6.125 inches
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Flange
MRC:
The pressure at which an item is designed to operate.BGST
Pressure Rating:
165.0 pounds per square inch
MRC:
The length of a straight line which passes through the center of an outlet bolt circle,and terminates at the circumference.BHCS
Outlet Bolt Circle Diameter:
4.063 inches
MRC:
The number of outlet bolt hole(s) on the item.BHCT
Outlet Bolt Hole Quantity:
5
MRC:
The length of a straight line which passes through the center of an outlet bolt hole,and terminates at the circumference.BHCW
Outlet Bolt Hole Diameter:
0.688 inches
MRC:
The length of a straight line which passes through the center of the inlet flange,and terminates at the inside circumference.CCFS
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the inlet flange,and terminates at the inside circumference.CCFS
Inlet Flange Inside Diameter:
1.500 inches
MRC:
The length of a straight line which passes through the center of the outlet flange,and terminates at the inside circumference.CCGK
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the outlet flange,and terminates at the inside circumference.CCGK
Outlet Flange Inside Diameter:
1.500 inches
MRC:
Indicates the type of flow provided.CCZS
Flow Type:
Vertical
MRC:
Indicates the type of drain hole connection provided.CDQC
Drain Hole Connection Type:
Drilled flange
MRC:
The length of a straight line which passes through the center of a drain hole flange bolt circle,and terminates at the circumference.CDQD
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of a drain hole flange bolt circle,and terminates at the circumference.CDQD
Drain Hole Flange Bolt Circle Diameter:
3.188 inches
MRC:
The number of drain hole flange bolt holes provided.CDQF
Err Default:
Err default
MRC:
The number of drain hole flange bolt holes provided.CDQF
Drain Hole Flange Bolt Hole Quantity:
4
MRC:
The length of a straight line which passes through the center of a drain hole flange bolt hole,and terminates at the circumference.CDQG
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of a drain hole flange bolt hole,and terminates at the circumference.CDQG
Drain Hole Flange Bolt Hole Diameter:
0.563 inches
MRC:
The distance between inlet face and outlet face connections.CDQJ
Distance Between Inlet Face And Outlet Face Connections:
12.000 inches
MRC:
The distance between the centerline of drain connection and face of outlet connection.CDQM
Err Default:
Err default
MRC:
The distance between the centerline of drain connection and face of outlet connection.CDQM
Distance Between Drain Connection Centerline And Outlet Connection Face:
9.313 inches
MRC:
Indicates the service type for which the item is designed.CFNN
Service Type For Which Designed:
Steam moisture
MRC:
The number of self-contained baffles provided.CFNP
Err Default:
Err default
MRC:
The number of self-contained baffles provided.CFNP
Self-contained Baffle Quantity:
1
MRC:
Designates the size of the nominal diameter of the drain hole connection pipe.CGMG
Drain Hole Connection Pipe Size:
1.000 inches
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Bronze
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy