Beschreibung:
Extractor Post Fuseholder
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Panel mounted type
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 3.750 inches and 4.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.813 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.188 inches
MRC:
The number of mounting holes provided.ABTJ
Mounting Hole Quantity:
2
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dripproof
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the mounting hole(s).AEVB
Mounting Hole Style:
2 bushing mounting w/2 holes
MRC:
The element,compound,or mixture of which the contact/s/ is fabricated,excluding any surface treatment.AFRG
Contact Material:
Beryllium copper
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the contact surface.AFRH
Contact Surface Treatment:
Silver plated, qq-s-365
MRC:
The means in which the item signals the interruption of a circuit.AFXH
Interruption Indicator Method:
Neon lamp
MRC:
The number of fuses the item is designed to accommodate /including spares/.AGUE
Fuse Accommodation Quantity:
2
MRC:
A measurement of the longest dimension of a fuse the item can accommodate.AGUJ
Accommodated Fuse Length:
1.250 inches
MRC:
The length of a straight line which passes through the center of the accommodated ferrule,and terminates at the circumference.AGUK
Accommodated Ferrule Diameter:
0.250 inches
MRC:
The rated ohmic value of the resistor/s/ furnished with the item.AGUN
Resistor Rating:
120.0 kilohms
MRC:
The minimum to maximum voltage at which the indicating lamp circuit is designed to operate,expressed in volts.AGUP
Indicating Lamp Voltage Range In Volts:
+90.0/+250.0
Length From Front Protrusion To Mounting Surface:
0.813 inches
Center To Center Distance Between Outside Mounting Holes Along Width:
0.938 inches
MRC:
The length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread.AJYN
Screw Thread Diameter:
0.164 inches
MRC:
The amount of electrical current the item is designed to carry,expressed in amperes.CQJL
Current Carrying Rating In Amps:
30.0
MRC:
Indicates the type of fuse terminations which the item will accommodate.CSNM
Fuse Terminal Type Accommodated:
Ferrule
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
250.0
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-f-19207/1 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 threaded stud