Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Multimeter
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/fsq-21 (v) 1
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Meter, test leads, soft case, user manual
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Digital display
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Hand held
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
+0.0/+2.0 at full scale 1st indicator single range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
+0.0/+1.0 at full scale 2nd indicator single range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
+0.0/+1.0 at full scale 3rd indicator single range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
+0.0/+1.0 at full scale 4th indicator single range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
+0.0/+1.9 at full scale 5th indicator single range
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Internal or external
MRC:
Indicates the type of display provided.BFQN
Display Type:
Liquid crystal
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
4
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+600.0 amperes, ac 1st indicator single range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+600.0 volts, ac 2nd indicator single range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+6000.0 ohms 4th indicator single range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+600.0 volts, dc 3rd indicator single range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+10.0/+1000.0 microfarads 5th indicator single range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Autoranging
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Agav
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
Aa1.4
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Handheld clamp-on true-rms meter measuring amps, voltage, and resistance
MRC:
Indicates the date the item was entered into mil-hdbk-300.NTRD
Entry Date:
11-10-06
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Clamp-on