Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
ft12aess-lea-1
Informationen zum Teil
Ft series turbine flowmeter, mounted carrier, ball bearing, accuracy +/-1.0 percent
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Rate Of Flow Transmitter
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.900 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.700 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
2000.0 hertz
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.700 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Impeller wheel and motion
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Pacer dawn
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
10.0 millivolts
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
1
MRC:
The name of the government agency or commercial organization controlling the electrical connection.ASKY
Electrical Connection Controlling Agency:
Military specification
MRC:
The identifying number assigned by the government agency or commercial organization controlling the electrical connection.ASKZ
Electrical Connection Identifying Number:
Ms310210sl-4p
MRC:
The number of mechanical connections provided.ASSB
Mechanical Connection Quantity:
2
MRC:
Designates the thread size,diameter,or the like,of the mechanical connection.ASSC
Mechanical Connection Size:
3/4 inch ms33656
MRC:
The minimum and maximum limits of measurement indicated by the item.BGNL
Measurement Range:
+7.6/+76.0 liters per hour and +2.0/+20.0 gallons per minute
MRC:
The number of alternating current phases.FAAZ
Phase:
Single